Adjust-a-Sink K100 Series Installation Instructions Manual Download Page 6

 

 

6 of 11 

 
The shampoo bowl is shipped directly from the manufacturer.  It is possible that there may be 
slight variations in bowls.  If the 3-Stage Telescoping Drain system IS NOT adjusted properly 
at installation, damage or breakage of the drain system may result - We have attached the 
bracket on the 3-Stage Telescoping Drain system, but it must be properly adjusted during 
installation. 

 

IMPORTANT: Do not trim or alter the Telescopic Drain in any way.  All components that make 
up the Telescopic Drain Pipe Subassembly are integrated and work together.  Altering its 
design will cause premature if not total failure of the telescopic drain mechanism. 

 

3F.

 Now connect the bottom of the Drain Pipe Subassembly to the wastewater drain pipe using a 

UPC approved PVC P-Trap (not supplied).  Use appropriate plumbing methods to seal and secure 
the P-trap to the drain and the roughed in 1 ½” waste drain.  

Do not glue the P-Trap until you 

conduct the Initial Testing Procedure noted below. 

 
Keep in mind that the Riser Pipe telescopes up and down 

within

 the Drain Pipe Subassembly.  

Consider proper alignment when performing the final connection of the P-Trap to the Drain Pipe 
Subassembly and wastewater drainpipe.  The Riser Pipe cannot be allowed to bind; the motion 
should be smooth and continuous.  

After P-Trap installation and proper alignment and smooth 

action are achieved, connect the Riser Pipe to the basket strainer and tighten all associated 
hardware.  Care should be used so as to not cross thread the riser pipe nut onto the basket 
strainer threads – make sure the brass screws on the drain are in alignment on each side of 
the drain after the riser pipe nut has been tightened onto the basket

 

strainer

 –

 see picture on 

page 8 (lower left). 

 

 
INITIAL TESTING PROCEDURE 

 

• 

Raise and lower the unit all the way up and down several times to be sure it is operating properly, 
without binding 

before and after

 connecting it to the building drain.  

 

 

• 

IMPORTANT:

 

Be sure there is about ¼” total slack in the cable linkage system when the 

unit is fully extended as described above. It is important that the lift system limits out prior 
to the drain extending to its full range.  Make any minor adjustments that are needed to 
keep the lift system from binding and to ensure that the lift system limits out prior to the 3-
Stage Telescopic Drain Assembly extending to its full range.  See photos on pages 7 and 8.

 

 

• 

Now ensure that all of the parts are tightened securely and glue the 2” x 1½” PVC Reducer/ 
Coupling to the P-trap and wall drain.   Care should be used to ensure you do NOT cause strain 
or binding on the vertical 3-Stage Telescoping Drain Assembly. 

 

3G

.

 Connect

 the provided flexible Water Supply Lines to both the faucet and the water supply 

shutoffs.  Use care and good judgment when installing the flexible lines so they are free and 
unobstructed when traveling with the elevating shampoo bowl. 

Summary of Contents for K100 Series

Page 1: ...ystem can be installed in most work areas with the proper water and waste connections there are necessary steps that are very important to follow to ensure the proper operation of the Adjust a Sink Re...

Page 2: ...n the finished floor The installer should verify that there is sufficient space to mount this panel also keeping in mind that the Lift Backsplash itself will elevate an additional 12 in height The mou...

Page 3: ...gh in through the floor are permissible however the installation becomes the responsibility of the installer 1B Drilling Hole Cutting the necessary holes in the Mounting Panel for water supply lines a...

Page 4: ...Wall Mounting Panel requires a different installation arrangement it is the installer s responsibility to calculate verify and drill the panel according to the guidelines already established Again re...

Page 5: ...sition extend the Telescoping drain to the basket strainer Connect the slip joint nut to the basket strainer make sure to use the nylon gasket provided with the basket strainer Make sure the drain cab...

Page 6: ...mooth action are achieved connect the Riser Pipe to the basket strainer and tighten all associated hardware Care should be used so as to not cross thread the riser pipe nut onto the basket strainer th...

Page 7: ...y hanging the shroud on the single stud on the right side of the lift panel Hand tighten the nylon nut to the stud Loosen the three nylon cap screws on the left lift shaft just enough to slide the shr...

Page 8: ...bracket Model shown has hot cold shut off valves inside of cabinet Note Ensure drain is level perpendicular to floor Note Nut for adjusting the sink angle Note The lift system limits out prior to the...

Page 9: ...D COULD ALSO CAUSE THE PLUMBING TO LEAK Lubrication When the sink will not be in use for a period of time or over night lower the sink to its lowest position This allows the shaft to stay lubricated i...

Page 10: ...neck of the shampoo bowl are aligned vertically The client will usually prefer a more upright seating position We suggest the use of an adjustable back fixed position shampoo chair if possible 3 Lowe...

Page 11: ...11 of 11 Operation of the Adjust a Sink cont Position the Client Like This Not Like This Note Proper Neck Bowl Position...

Page 12: ...OOR REF WASTE DRAIN STUBOUT 8 REF 4 WATER SUPPLY STUBOUT REF FOR WATER SUPPLY CLEARANCE HOLES 7 8 LINES A 2 1 2 22 11 B 33 4 1 8 2x 2 1 4 CLEARANCE HOLE FOR WASTE DRAIN PIPE NOTE FOR USE WITH MARBLE P...

Reviews: