![ADJ ZIPPER User Instructions Download Page 7](http://html1.mh-extra.com/html/adj/zipper/zipper_user-instructions_2851831007.webp)
ADJ Products, LLC - www.adj.com - Zipper Instruction Manual Page 6
chained and cannot be split.
Zipper
Set Up
Notice:
Be sure to follow figures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR’s outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
DMX512 IN
3-PIN XLR
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OUT
3-PIN XLR
Figure 2
Figure 3
1 Ground
1 Ground
XLR Male Socket
XLR Pin Configuration
3 Hot
2 Cold
2 Cold
3 Hot
XLR Female Socket
Pin 3 = Data True (positive)
Pin 2 = Data Compliment (negative)
Pin 1 = Ground
Special Note: Line Termination.
When longer runs of cable are
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
DMX512 IN
3-PIN XLR
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OUT
3-PIN XLR
Figure 4
ADJ Products, LLC - www.adj.com - Zipper Instruction Manual Page 21
Zipper
Dimmer Curve Chart
(Fade Time)
(Fade Time)
Ramp Effect
Standard
Stage
TV
Architectural
Theatre
Zipper
Photometric Chart
1.0
2.0
3.0
4.0
Distance(m)
0
0m( )
5.0
30
1.0
2.0
3.0
4.0
Distance(m)
0
0m( )
5.0
30
5.0
10.0
15.0
20.0
Distance(m)
0
0m( )
Radiance Beam 5R
1
Diameter(m)
0.4
0.7
1.21
1.5
5.0
10.0
20.0
Distance(m)
0
0m( )
Radiance Beam 2R Pro
1
0
5.0
7.0
10.0
Distance(m)
0
0m( )
Inno Spot 700
15
5.0
10.0
20.0
Distance(m)
0
0m( )
Radiance Beam 2R Pro
1
3.0
5.0
7.0
10.0
Distance(m)
0
0m( )
29500
10
Photometrics diagram
12100
5880
3000
Diameter(m)
0.5
0.9
1.2
1.7
2600
60 LUX
1000
538
275
10
60
Diameter(m)
3.5
5.8
8.1
13.8
5.0
10.0
15.0
20.0
Distance(m)
0
0m( )
XP-5R BEAM
1.0
2.0
3.0
4.0
5.0
Distance(m)
0
0m( )
10
40000
12000
5200
1900
3100
3.8
1.0
2.0
3.0
4.0
5.0
Distance(m)
0
0m( )
60
65000
29500
12600
4400
6900
10
7200
2000
900
360
540
5.0
10.0
15.0
20.0
Distance(m)
0
0m( )
26
XP-15R SZ
33000
8300
3700
2035
6
1700
470
200
106
5.0
10.0
15.0
20.0
Distance(m)
0
0m( )
26
XP-15R SZ
33000
8300
3700
2035
6
1700
470
200
106
5.0
10.0
15.0
20.0
Distance(m)
0
0m( )
R B-16R
1
Diameter(m)
2.2
4.4
6.7
8.9
Diameter(m)
0.5
1.0
1.6
2.1
2.6
Diameter(m)
0.5
1.0
1.6
2.1
2.6
1.0
2.0
3.0
4.0
Distance(m)
0
0m( )
5.0
TVL1000 II
30
Diameter(m)
0.5
1.0
1.6
2.1
2.6
1.0
2.0
3.0
4.0
Distance(m)
0
0m( )
5.0
3.5
Diameter(m)
0.065
0.135
0.172
0.256
0.325
1.0
2.0
3.0
4.0
Distance(m)
0
0m( )
5.0
1.5
Diameter(m)
0.017
0.035
0.052
0.07
0.087
1.0
2.0
3.0
4.0
Distance(m)
0
0m( )
5.0
13
Diameter(m)
0.228
0.456
0.684
0.911
1.139
1.0
2.0
3.0
4.0
Distance(m)
0
0m( )
5.0
Diameter(m)
0.246
0.491
0.737
0.982
1.228
14
1.0
Distance(m)
0
0m( )
Diameter(m)
0.05
5.0
0.25
8.0
0.39
10.0
0.49
15.0
0.74
20.0
1.02
25.0
1.26
3
1.0
2.0
3.0
4.0
Distance(m)
0
0m( )
5.0
28
Diameter(m)
0.499
0.997
1.496
1.995
2.493
1.0
2.0
3.0
4.0
Distance(m)
0
0m( )
5.0
1.5
Diameter(m)
0.35
0.07
0.105
0.14
0.175
1.0
2.0
3.0
4.0
Distance(m)
0
0m( )
W
5.0
2
B
G
R
(
)
LUX
8200
2650
1200
695
441
31000
8400
4100
2050
1350
660
200
96
61
41
53000
16000
7500
4400
2800
Diameter(m)
0.35
0.07
0.105
0.14
0.175
With this feature you can connect the fixtures to one another
using the IEC input and output sockets. The quantity that can be
connected is 10 fixtures maximum for 120V and 18 fixtures maxi-
mum for 240V. After the maximum fixtures has been reached you
will need to use a new power outlet. They must be the same fix-
tures. DO NOT mix fixtures.
Zipper
Power Cord Daisy Chain