ADJ ZIPPER User Instructions Download Page 14

ADJ Products, LLC  -  www.adj.com  - Zipper Instruction Manual Page 14

Operating Modes:  The  Zipper  can  operate  in  three  different 

modes. In each mode you can run the fixture as a stand alone 

fixture or in a master/slave confiugration. This next section will 

detail the differences in the operating modes.

• Sound Active mode -

The fixture will react to sound, chasing through the built-in programs. 

• Show mode -

The fixture will run one of 16 shows. 

• DMX control mode -

This function will allow you to control each individual fixtures traits 

with a standard DMX-512 controller.

Universal DMX Control: 

This function allows you to use a univer-

sal DMX-512 controller to control the chases and patterns, dimmer 

and strobe. A DMX controller allows you to create unique programs 

tailored to your individual needs. 

1. The Zipper has 3 DMX Modes. See pages 17-20 for detailed

description of the DMX modes, values, and traits.

2. To control your fixture in DMX mode, follow the set-up procedures

on pages 5-7 as well as the set-up specifications that are includ-

  ed with your DMX controller. 

3. Use your DMX controller’s faders to control the various DMX fix- 

  ture traits.

4. Follow the instructions on page 9 to set your DMX channel mode

and the DMX address.

5. For longer cable runs (more than a 100 feet) use a terminator on

the last fixture.

6. For help operating in DMX mode consult the manual included

with your DMX controller.

Sound Active Mode: 

This mode allows either a single unit or several 

units linked together, to run to the beat of the music.   

1.  Press the MENU button until “

SOUN

” is displayed, and press

  ENTER. Press the UP or DOWN buttons so that “

ON

” is dis- 

  played and press ENTER.

2. To adjust the sound sensitivity level press the MENU button until

 “SENS” is displayed, and press ENTER. Use the UP or DOWN 

buttons to adjust the sensitivity level, “0” being least sensitive, 

 Zipper 

Operation

ADJ Products, LLC  -  www.adj.com  - Zipper Instruction Manual Page 13

TEST

 - This function will run a self test program. The test

program will test pan/tilt movement and colors.

1. Press the MENU button until “

TEST

” is displayed, press

ENTER.
2. The fixture will now run a self test. Press MENU to exit.

FHRS

 - With this function you can display the running

time of the unit.

1. Press the MENU button until “

FHRS

” is displayed, press

ENTER.
2. The running time of the fixture will now be displayed. Press

MENU to exit.

VER

 - With this function you can display the software ver-

sion of the unit.

1. Press the MENU button until “

VER

” is displayed, press

ENTER.
2. The software version will now be displayed. Press MENU to

exit

RSET

 - Use this function to reset the unit.

1. Press the MENU button until “

RSET

” is displayed, press

ENTER.
2. The fixture will now reset.

 Zipper 

System Menu

Summary of Contents for ZIPPER

Page 1: ...S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 2650 Fax 323 725 6100 Web www adj com E mail info americandj com A D J Supply Europe B V Junostraat 2 6468 EW Kerkrade Netherlands service adjgroup e...

Page 2: ...ufficient and negligent as sembly installation rigging and operation of this product Europe Energy Saving Notice Energy Saving Matters EuP 2009 125 EC Saving electric energy is a key to help protectin...

Page 3: ...e show mode DMX controlled The Zipper has 3 DMX mode 1 channel mode 3 channel mode and 11 channel mode The Zipper can operate as a stand alone fixture or in a Master Slave configuration For best resul...

Page 4: ...any unauthor ized modification to this unit Zipper Handling Precautions Zipper Warranty Registration The Zipper carries a 2 year 730 days limited warranty Please fill out the enclosed warranty card to...

Page 5: ...t must be shipped in it s original package No accessories should be shipped with the product If any accessories are shipped with the product ADJ Products LLC shall have no liability whatsoever for los...

Page 6: ...ler require a approved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shiel...

Page 7: ...X T will decrease the possibilities of erratic behavior DMX512 IN 3 PIN XLR SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER...

Page 8: ...ils a proper cable conversion Conductor 5 Pin XLR Male In 3 Pin XLR Female Out Pin 1 Pin 5 Do Not Use Pin 4 Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment...

Page 9: ...ISE ROTATION SLOW FAST 128 255 COUNTER CLOCKWISE ROTATION FAST SLOW 3 BARREL 3 0 STOP 1 127 CLOCKWISE ROTATION SLOW FAST 128 255 COUNTER CLOCKWISE ROTATION FAST SLOW 4 BARREL 4 0 STOP 1 127 CLOCKWISE...

Page 10: ...ER to confim and exit SLND This will let you set unit as a slave in a master slave configuration 1 Press the MENU button until SLND is displayed press ENTER Either MAST SL 1 or SL 2 will be displayed...

Page 11: ...UN is displayed press ENTER 2 The display will show either ON or OFF Press the UP or DOWN buttons to select ON to activate sound active mode or OFF to deactivate sound active mode 3 Press ENTER then p...

Page 12: ...ll stay in the last DMX setting If power is applied and this mode is set the unit will automatically go into the last DMX set up 3 Press ENTER to confirm your desired set up DIND In this mode you can...

Page 13: ...to run one of 16 shows that you choose Show mode can run with or without sound active mode 1 Press the MENU button until SHND is displayed and press ENTER 2 Press the UP or DOWN buttons until you find...

Page 14: ...ore than a 100 feet use a terminator on the last fixture 6 For help operating in DMX mode consult the manual included with your DMX controller Sound Active Mode This mode allows either a single unit o...