Vizi Beam RXONE
Cleaning
Fixture Cleaning: Due to fog residue, smoke, and dust, cleaning the internal and external optical
lenses and mirror should be carried out periodically to optimize light output. Cleaning frequency de-
pends on the environment in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy
club use, cleaning on a monthly basis is recommended. Periodic cleaning will ensure longevity and
crisp output.
• Use normal glass cleaner and a soft cloth to wipe down the outside casing.
• Use a brush to wipe down the cooling vents and fan grill.
• Clean the external optics and mirror with glass cleaner and a soft cloth every 20 days.
• Clean the internal optics with glass cleaner and a soft cloth every 30-60 days.
• Always be sure to dry all parts completely before plugging the unit back in.
Vizi Beam RXONE
Trouble Shooting
Trouble Shooting: Listed below are a few common problems that you may encounter, with solu-
tions.
Unit not responding to DMX:
Check that the DMX cables are connected properly and are wired correctly (pin 3 is “hot”; on some
other DMX devices pin 2 may be ‘hot’). Also, check that all cables are connected to the right con-
nectors; it does matter which way the inputs and outputs are connected.
No light output from the unit:
• Make sure the lamp is “On”.
• Be sure the external fuse has not blown. The fuse is located at the rear panel of the unit.
• Remove the “Lamp Access” shell and be sure the two wires are connected to the lamp
• Be sure the fuse holder is completely and properly seated.
Unit does not respond to sound:
• Quiet or high pitched sounds will not activate the unit.
• Make sure that Sound Active mode is activated.
ADJ Products, LLC - www.adj.com - Vizi Beam RXONE User Manual Page 37