Safety Precautions

•  To reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

•  Do not spill water or other liquids into or on to your unit.

•  Do not attempt to operate this unit if the power cord has been frayed or broken. 

•  Do not attempt to remove or break off the ground prong from the electrical cord. This prong is 

used to reduce the risk of electrical shock and fire in case of an internal short.

•  Disconnect from main power before making any type of connection.

•  Do not remove the cover under any conditions. There are no user serviceable parts inside.

•  Never operate with the cover removed.

•  Never plug this unit into a dimmer pack.

•  Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” 

(15cm) between this device and a wall.

•  Do not attempt to operate this unit if it has been damaged.

•  This unit is intended for indoor use only. Use of this product outdoors voids all warranties.

•  During long periods of non-use, disconnect the unit’s main power.

•  Always mount this unit in a safe and stable manner.

•  Power-supply cords should be routed so that they are not likely to be walked on or pinched by 

items placed upon or against them, paying particular attention to the point at which they exit from 

the unit.

•  Cleaning - The fixture should be cleaned only as recommended by the manufacturer. See the 

Cleaning section of this manual for cleaning details.

•  Heat - The appliance should be situated away from heat sources such as radiators, heat registers, 

stoves, or other appliances (including amplifiers) that produce heat.

•  The fixture should be serviced by qualified service personnel when:

A.  The power-supply cord or the plug has been damaged.

B.  Objects have fallen onto, or liquid has been spilled into, the appliance.

C.  The appliance has been exposed to rain or water.

D.  The appliance does not appear to operate normally or exhibits a marked change in perfor-

mance.

Summary of Contents for FLAT PAR TW5

Page 1: ...User Manual FLAT PAR TW5 Rev 04 2021...

Page 2: ...red trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to an...

Page 3: ...Color mode and DMX control mode To optimize the performance of this product please read these operating instructions carefully to familiarize yourself with the basic operations of this unit These inst...

Page 4: ...e 3 Channel Mode 4 Channel Mode 5 Channel Mode 8 Channel Mode and 9 Channel Mode ADJ LED RC3 compatiable Not Included Power Cord Daisy Chain see the Power Cord Daisy Chain section of this manual The F...

Page 5: ...e this unit if it has been damaged This unit is intended for indoor use only Use of this product outdoors voids all warranties During long periods of non use disconnect the unit s main power Always mo...

Page 6: ...ral DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address...

Page 7: ...A terminator is a 110 120 ohm 1 4 watt resistor which is connected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in you...

Page 8: ...colors to remain static or adjust the intensity of each color to create a custom color DMX control mode This function will allow you to control individual DMX traits with a standard DMX 512 controller...

Page 9: ...run ning together The running speed is adjustable in all 3 modes 2 Plug the fixture in and press the MODE button until either AF X AJ X or A JF is displayed AF X Color Fade mode with 8 Color Fade mode...

Page 10: ...al is lost or interrupted It also determines the mode that the fixture will default to when it is powered on 1 Press the MODE button until the DMX address is displayed 2 Press the SET UP button until...

Page 11: ...ary 1 Using approved DMX data cables daisy chain your units together via the XLR connectors on the rear of the units Remember the Male XLR connector is the input and the Female XLR connec tor is the o...

Page 12: ...ing DMX State and dimming curve selection Each press of this button will change to the next mode In DMX State mode press the the and buttons to scroll through the DMX state modes See the Operating Ins...

Page 13: ...te When setting the DMX address an LED color will glow each time a key is pressed When you have set the DMX address correctly all LED s will flash 2 3 times Example To Set DMX Address 1 Press S 0 0 1...

Page 14: ...ADJ Products LLC www adj com Flat Par TW5 User Manual Page 14 Flat Par TW5 2 Channel Mode Flat Par TW5 3 Channel Mode Flat Par TW5 4 Channel Mode...

Page 15: ...ADJ Products LLC www adj com Flat Par TW5 User Manual Page 15 Flat Par TW5 5 Channel Mode...

Page 16: ...ADJ Products LLC www adj com Flat Par TW5 User Manual Page 16 Flat Par TW5 8 Channel Mode...

Page 17: ...at Par TW5 8 Channel Mode When channel 6 is being used channels 1 3 cannot be used When channel 7 is between the values of 128 239 channel 8 will control the program speed When channel 7 is between th...

Page 18: ...ADJ Products LLC www adj com Flat Par TW5 User Manual Page 18 Flat Par TW5 9 Channel Mode...

Page 19: ...en Channel 6 is being used Channels 1 3 cannot be used When Channel 7 is set to DMX values 128 239 Channel 8 will control the speed of the programs When Channel 7 is set to DMC values 240 255 Channel...

Page 20: ...olor22 160 167 0 83 115 Color6 32 39 254 121 0 Color23 168 175 0 97 166 Color7 40 47 176 17 0 Color24 176 183 1 100 167 Color8 48 55 96 0 11 Color25 184 191 0 40 86 Color9 56 63 234 139 171 Color26 19...

Page 21: ...Flat Par TW5 Photometric Chart ADJ Products LLC www adj com Flat Par TW5 User Manual Page 21 Flat Par TW5 Dimmer Curve Chart...

Page 22: ...ed below are a few common problems the user may encounter with solutions Unit not responding to DMX Check that the DMX cables are connected and wired correctly pin 3 is hot on some other DMX devices p...

Page 23: ...eplace defective parts at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsi...

Page 24: ...Amber Wavelength 590 595 NM CRI Values Cool White 70 80 Warm White 70 80 Amber None Auto Sensing Voltage This fixture contains an automatic voltage switch which will automatically sense the voltage wh...

Page 25: ...ADJ Products LLC www adj com Flat Par TW5 User Manual Page 25...

Page 26: ......