Technical manual ADITRAT
10
PROBLEM:
THE SOFTENER DOES NOT REGENERATE ALTHOUGH IT SUCKS BRINE.
(Salted water comes out of the drain just after sucking brine).
The lower feed pipe is short or split.
The water with brine goes directly to the drain
without passing through the tank (which means
without passing through the resin).
Change the feed pipe.
Check that this pipe connection is not
loose or broken.
Change the lower connection. Change
connection pipe.
High content of chlorides, nitrates or iron
compounds in the water from the mains.
Analyze again the water and rectify
according to the result of the new
analysis.
PROBLEM:
PRESENCE OF SALT IN THE CONSUMPTION LINE
The time of slow washing is too short.
Increase it.
The injector is small (it needs too much time for
sucking brine.)
Change the injector for another one of
greater size.
Suction of excessive quantity of brine.
Check the floater height in the salt valve.
Lower it.
PROBLEM:
WATER KEEPS ON COMING OUT FROM THE DRAIN AFTER THE
REGENERATION HAS ENDED.
Damaged drain valve.
It does not adjust correctly, or lack of a O-ring
gasket.
Change the valve.
Clean the drain valve. Put a O-ring
gasket.
Programme cams are loose.
Tighten the fixing screw.
The control pinion for regeneration is jammed or
the cogs worn down.
Change the control pinion.
**
OBSERVATIONS.
-
It is recommended that the power point of the supply system (from the mains) is provided
with a good earth connection, no higher than 16
Ω
.
-
In case you have to tighten or loosen the tank valve, it is recommended to do it with the
maximum precaution, without levering up one of the connections, in order not to break its
base. Consider that, even if NORYL is a resistant material, it has a low limit of flexibility.