2.4. MAINTENANCE GUIDE.
-
The filter installed inside the injector must be periodically cleaned and checked.
-
It is recommended to put a filter for impurities in the installation, before the softener.
PROBLEM
: AFTER REALIZING A COMPLETE REGENERATION, THE HARDNESS IS > 5º F
POSSIBLE ORIGIN
CORRECTION
Increase of the planned water quantity.
Check the consumption.
Adjust again the programmer in case you
need more than one regeneration.
Not sufficient brine quantity.
Raise the position of the floater in the
brine valve.
Excessively fast brine suction.
Change the injector disk for one of greater
number.
Check the height of the floater.
Low concentration of brine due to a reduction of
the diameter or to a constriction in the suction
pipe.
Eliminate the constriction.
Change the suction pipe.
Low concentration of brine due to dirtiness in the
injector passage grooves.
Clean the injector disk.
Clean the injector filter.
Short times of counter-washing and total times
of suction.
Increase.
Change of water quality
(Content of Ca, Mg in bicarbonates)
Analyze the water from the mains.