2012-03-29 Manual Q-8V100 and S-25A30 Rev. 0.1
preliminary
9
2.2.5. Repair and modification
Repair, modification and replacement of parts shall be done only by Adimec to maintain
compliance
with the directive 89/336/EEC electromagnetic compatibility and directive 72/23/EEC low
voltage directive and the international standards.
2.2.6. Peripheral equipment
For safety, use an external SELV qualified power supply. Maximum current 1 A.
For safety, peripheral equipment must either be double isolated or SELV qualified.
2.2.7. Mounting / Mechanical
Connectors
Take care during handling of the camera. The Camera Link connector and the power
connector should not be damaged.
The maximum tightening torque for the Camera Link connector may not exceed 0.26 Nm.
Prevent the entry of foreign objects or dirt into the connectors, as this will result in unreliable
operation or damage.
Mounting screws
Take notice of the maximum length of the screws that may be used for mounting of the
camera. Using screws too long can cause damage to the camera. Maximum screw length: 5
mm.