2012-03-29 Manual Q-8V100 and S-25A30 Rev. 0.1
preliminary
20
x=0 for the automatic mode: The strobe will become active during the integration time
(regardless operating mode MOx)
x=1 for the programmed mode; both delay time after start of integration as well as the
duration of the active state is programmed.
Note that a flash strobe length that extends after the end of integration time is not possible.
The camera will end the flash strobe automatically.
The timing can be programmed:
Command Syntax:
FSTx;y
FST?
x is the delay between start of integration and the transition of the flash strobe to the active
state. y is the length of the flash strobe active state. Both x and y are in units of 1 µs and
range from 0 to 100,000.
Both are without the additional intrinsic response delay of the flash strobe which is
mentioned in section 3.1.1.
6.5. Defect pixel correction
A defect correction is available that replaces a defect pixel by a weighted average of those
its 4 adjacent pixels that are not defect. The neighbors are labeled N, S, E, and W in figure
6.1. Their weights are listed in table 6.1 for the possible situations.
Figure 6.1: Surrounding of defect pixel
#
Is defect:
Weight of adjacent pixel:
N
S
E
W
kN
kS
kE
kW
0
0
0
0
0
1/4
1/4
1/4
1/4
1
0
0
0
1
1/4
1/4
1/2
0
2
0
0
1
0
1/4
1/4
0
1/2
4
0
1
0
0
1/2
0
1/4
1/4
8
1
0
0
0
0
1/2
1/4
1/4
3
0
0
1
1
1/2
1/2
0
0
5
0
1
0
1
1/2
0
1/2
0
6
0
1
1
0
1/2
0
0
1/2
9
1
0
0
1
0
1/2
1/2
0
10
1
0
1
0
0
1/2
0
1/2
12
1
1
0
0
0
0
1/2
1/2
N
S
E
W
?
0
1
-1
0
1
-1