About this mAnuAl

About this manual

1.1  Objective

This  manual  describes  the  special  requirements  on  installation,  wiring,  commissioning,  and 

operation  of  ADICOS  detectors  for  explosive  atmospheres  up  to  ATEX  zone  20.  They  are 

exclusively addressed to knowledgeable specialist personnel (–› Chap. 2, Safety instructions).

1.2  Explanation of Symbols

This manual features a continuous structure for best possible comprehension. The following 

labels are used. 

Warning signs

The following types of notes are used through this manual.

DANGER!

This combination of symbol and signal word indicates an immediately

dangerous situation that will lead to death or severe injuries if not avoided.

WARNING!

This combination of symbol and signal word indicates a possibly dangerous

situation that could lead to death or severe injuries if not avoided.

Explosion Protection

This information type signals measures that must be implemented for maintain

-

ing the Explosion protection.

Tips and recommendations

Helpful tips and recommendations as well as information to ensure efficient and 

uninterrupted use.

1.3 

Storing the Manual

Store this manual easily reachable and in direct vicinity of the detector system to enable use 

as needed.

Summary of Contents for GSME-X20

Page 1: ...dustrieelektronik GmbH Helmholtzstr 21 38 40 41747 Viersen Germany 49 2162 3703 0 info gte de GSME X20 Supplementary Instruction Manual for GSME X20 Fire Gas Detector IP64 DO NOT OPEN IN GAS LOADED AT...

Page 2: ...oltzstr 21 38 40 41747 Viersen GERMANY Support hotline 49 2162 3703 0 E Mail support adicos gte de 2023 GTE Industrieelektronik GmbH This document and all figures contained may not be copied changed o...

Page 3: ...for fire gas detection in industrial environments and already in the incipient stage With the ADICOS software all detector states and concentration curves can be displayed graphically Sensitivities as...

Page 4: ...6 2 3 Personnel Qualification 7 2 4 Handling Electrical Voltage 7 2 5 Modifications 7 2 6 Accessories and Spare Parts 7 3 Structure 8 3 1 Overview 8 3 2 Cable assignment 8 3 3 Display elements 9 4 In...

Page 5: ...notes are used through this manual DANGER This combination of symbol and signal word indicates an immediately dangerous situation that will lead to death or severe injuries if not avoided WARNING This...

Page 6: ...l Data must be met Any deviating use requires prior consultation with the manufacturer Compliance with this manual as well as all applicable country specific provisions is also part of the intended us...

Page 7: ...ectors requires an electrical voltage that can trigger an explosion in potentially explosive atmospheres Do not open enclosure De energize the entire detector system and secure against unintentionally...

Page 8: ...gland 3 2 Cable assignment Wire Color Signal Signal limit contact 1 black Operating voltage 21 6 40 V DC non polarized 1 white 2 black Relay output X6 e Alarm NO1 2 white Relay output X6 a Alarm NO1 3...

Page 9: ...lack NO 6 white C 3 3 Display elements Signal Dome The signal dome is a translucent element It includes the status LED to indicate the operating condition of the X20 detectors The light signals of the...

Page 10: ...explosion due to electrical voltage in hazardous areas The electronics of ADICOS GSME X20 works with an electrical voltage that can trigger an explosion in potentially explosive atmospheres Do not ope...

Page 11: ...x protected connection boxes with respective approval Do not bend connection cable Observe minimum bending radius Chap 9 Technical Data 5 Commissioning DANGER Risk of explosion due to electrical volta...

Page 12: ...plosion in potentially explosive atmospheres Do not open enclosure De energize the entire detector system and secure against unintentionally reactivation for all wiring work Replace the closed detecto...

Page 13: ...power consumption with heating VA 14 M Bus voltage signal V mA max 40 V non polarized max 30 mA Thermal physical data Ambient Temperature C 20 50 C Relative humidity 95 non condensing Sensor data Sens...

Page 14: ...able YR Year of production variable ART Nr Article number variable TEMP Ambient temperature IP Degree of protection COM Nr Communication number variabel VDC VA Voltage range maximum pow er consumption...

Page 15: ...15 ADICOS GSME X20 408 2410 004 EN22 Appendix 10 Appendix 10 1 ADICOS Mounting Plate A A 1 5 0 1 5 0 1 3 0 1 3 0 6 4 A A...

Page 16: ......

Reviews: