Troubleshooting and Diagnostics
27
Notes
If the function requires you to insert a cartridge,
c
will appear on the single-character
display. Within 60 seconds, insert a cartridge or the drive will exit Maintenance Mode.
If you insert an invalid or write-protected cartridge, a blinking
7
will appear on the
single-character display and the Status LED will be flashing amber and the LCD will
display ERROR! Media Error after the drive loads the tape. After several seconds the
drive will then unload the cartridge and exit Maintenance Mode.
If the function is successfully completed,
0
appears temporarily on the single-character display and the drive exits
Maintenance Mode
.
If the function fails, the
Status
LED will flash amber, an error code will be shown on the single-character display, and
the drive exits
Maintenance Mode
. To resolve an error refer to Table 4-2 Error Codes, elsewhere in this chapter.
To clear an error, cycle (remove, then reapply) power to the LTO standalone.
Exit Maintenance Mode
To select the
Exit Maintenance Mode
function, perform the following steps:
1.
Verify that the drive is in
Maintenance Mode
shown when the
Status
LED is solid amber.
The front panel indicators will display the following:
Indicator
State, Character, or Message
Status
LED
Amber, solid
Single-character display
0
LCD
Maint Mode: Select
Exit Maint Mode
2.
With
0
on the single-character display, press and hold the
Unload
button for three seconds to force the drive to exit
Maintenance Mode
(the
Status
LED is solid green).
The drive also exits
Maintenance Mode
automatically after it has completed a function or after 10 minutes if no action
has occurred.
Drive R/W Diagnostic
Use this function to direct the drive to execute built-in tests to determine whether it can properly load and unload cartridges, and read and
write data.
To select the
Drive R/W Diagnostic
, perform the following steps:
1.
Verify that the drive is in
Maintenance Mode
shown when the
Status
LED is solid amber.
2.
Press the
Unload
button once per second until the front panel indicators display the following:
Indicator
State, Character, or Message
Status
LED
Amber, solid
Single-character display
1
LCD
Maint Mode: Select
Drive R/W Diagnostic
Summary of Contents for LTO 200D
Page 1: ...LTO Standalone User s Guide LTO 200D and LTO 400D...
Page 6: ...vi Blank Page...
Page 10: ...x Blank Page...
Page 12: ...xii Blank Page...
Page 20: ...8 Introduction Blank Page...
Page 26: ...14 Installation Blank Page...
Page 34: ...22 Operation and Maintenance Blank Page...
Page 63: ...51 Index...