Appendix 1. List of commands for configuring converter
via the console port
When operating the converter through the console port, the user can both read and change the current
converter settings. The list of commands is given in the Table 8.
To access the settings in the console window, enter the password (default – adgt):
passw adgt
The responce will be:
Authorization successful
— if the password is correct;
Incorrect password
— if the password is wrong.
To request the parameter value, enter the command: get, space, parameter name. For example,
get rs485_2_port
To change the value of a parameter, enter the command: get, space, parameter name, space,
parameter value. If the value is within the allowed limits, it will return in response Set OK. For example,
set fixed_ip 192.168.88.1
Table 8. List of commands for configuring the converter.
Command
Description
Note
Feature
2
/?
help
List of available commands
R
curr_gw
Current network gateway
R
curr_ip
Current IP-address
R
curr_mac
Current MAC-address
R
curr_mask
Current subnet mask
R
def_mac
Factory MAC address
R
dhcp_client
Use set IP-address or get it from
DHCP
0 – set,
1 – from DHCP
R/W
firmware
SW version
R
fixed_dns
DNS-server address
R/W
fixed_gw
Defined default gateway
R/W
fixed_ip
Manually defined IP-address
R/W
fixed_mask
Defined net mask
R/W
mode_rs485
State of interface
RS485/RS-422
0 – Disabled port 1 and port 2
1 – Enabled port 1
2 – Enabled port 2
3 – Enabled port 1 and port 2
4 – Enabled port RS-422
R/W
password
Password to access settings
from 1 to 10 characters (latin
letters of different case, numbers)
R/W
Settings of RS-232 interface
rs232_auth
Authorization type
0 – no autorization
1 – authorization ADGT
R/W
rs232_baud
Interface port speed
from 600 to 115200 bit/sec
R/W
rs232_check_period
Ping Request Frequency
from 10 to 43200 seconds
R/W
2
R – read-only command, R/W – read and write command.