EDM Serial-to-Ethernet Converters
User Guide ver. 2.0 | 2021-09-01
Phone: +420 538 890 720
11
E-mail: [email protected]
4.
In the dialog box that opens, select the item
Internet Protocol version 4 (TCP/IPv4)
and click Properties button.
5.
In the protocol settings, select Use
following IP address and fill the lines IP-
address and Subnet mask manually.
The IP-address for local connection must
belong to the same subnet as the IP-address
of the converter. The converter has the
following default settings:
•
IP-address: 192.168.88.1
•
Subnet mask: 255.255.255.0
Accordingly, the IP-address in the connection
settings must be the same as the address of
the converter, except for the last digits. The
last digits can be any from 0 to 254 (except 0
and 254) as, for example:
•
IP-address: 192.168.88.2
•
Subnet mask: 255.255.255.0
Note: if the converter is connected to the network directly, it is not necessary to specify the
Default
gateway
. If the converter is located in the subnet which differs from the PC's one, the IP-address of
the converter must be specified as the gateway.
6.
Click OK. If the connection was successful, you can proceed to configuring the device through the
web interface.
Fig. 6. Internet Protocol version 4 (TCP/IPv4).
Fig. 7. Configuring the IP-address of the local connection.