ADGT EDM106 User Manual Download Page 13

 

EDM Serial-to-Ethernet Converters 

User Guide ver. 2.0 | 2021-09-01 

 

 

Phone: +420 538 890 720 

13 

E-mail: [email protected] 

4.

 

In the RS-232 Settings and RS-485/RS-422 Settings menues, configure parameters of the serial 
ports in accordance with the settings of the connected equipment. For each port, select the 
operating mode Client or Server and set its parameters. 

Save changes using the Submit button. 

Table 6. Configuring serial ports.

 

Parameter 

Default value 

Possible values 

 

RS-232 

RS-485/RS-422 

 

State 

Enabled 

-------- 

Closed

 

in menu Home 

Disabled port 1 

and port 2 

-------- 

Disabled 

in menu Home 

RS-232: disabled/enabled 
RS-485: disabled port 1 and port 2/ 

              enabled port 1/ 

              enabled port 2/ 

              enabled port 1 and port 2 

RS-422: disabled port 1 and port 2/ 

              enabled port RS-422 

Operation mode “TCP-server” (default) 

 Port number 

60001 

RS-485(1): 60002 

RS-422: 60002 

RS-485(2): 60003 

Number of TCP-port of server 

List of allowed Client 

IP-addresses (IP1-IP5) 

0.0.0.0 

(“White” list disabled, 

all connections are allowed) 

“White” list of IP-addresses of clients (

up to 

5 addresses

), which are allowed to connect 

the converter, when it operates in the 

"Server" mode 

Maximum number of 

incoming connections 

2, 1 

Operation mode “TCP-client” 

Port number 

60001 

RS-485(1): 60002 

RS-422: 60002 

RS-485(2): 60003 

Port of TCP-server, to which the connection 

will be made 

Server IP address 

0.0.0.0 

(not specified) 

IP-address of server, to which the 

connection will be made 

Authorization type 

No authorization 

No authorization, ADGT  

Serial number 

Each port has its own serial number 

15-digit number for registration on the 

server (when choosing an authorization 

type ADGT) 

 

Clearing the input buffer 
on connection 

not clear 

not clear, clear 

Maximum TCP Packet 
Length  

1024 byte 

1 – 1024 byte 

Force Transmit Timeout 

10 ms 

1 – 10000 milliseconds 

Inactivity Time 

30 sec 

1 – 216000 seconds 

Ping IP Address 

0.0.0.0 

(connection check disabled) 

To enable connection check, specify the IP-
address to ping the connection (ICMP-echo)  

Ping Request Frequency 

30 sec 

10 seconds – 43200 seconds 

Flow Control 

Disabled 

 

Enabled, Disabled 

Baud Rate 

9600 

600-115200 bit/sec 

Data bits 

8, 7 

Parity 

No check 

Even, Odd, No check 

Stop bits 

1, 0.5, 1.5, 2 

Summary of Contents for EDM106

Page 1: ...EDM Serial to Ethernet Converters User Guide...

Page 2: ...es hereinafter referred to as converters The manual contains information about the purpose design technical parameters and operating principles of the converters ADGT systems s r o reserves the right...

Page 3: ...Connector DB 9F of RS 232 interface 7 LED Indication 7 Chapter 2 Operating the converter 9 Connection and installation 9 Configuring EDM Converter 10 Configuring Converter via Web Interface 10 Config...

Page 4: ...r 120 Ohms and PVC tubing Cambrick Converter s features Independent interfaces RS 232 RS 485 RS 422 for connecting industrial devices Connection of up to 256 devices via RS 485 RS 422 interfaces 8 5V...

Page 5: ...n the model EDM106 G Output 8 5V x1 8 5V output for power supply of external devices Load current up to 50 mA Connector terminal block XP2 terminal VO step 3 81 mm PWR x1 Connector RJ 12 power supply...

Page 6: ...ay terminal block A1 Signal A RS 485 1 Output Y of RS 422 line B1 Signal B RS 485 1 Output Z of RS 422 line T T1 G G1 1 Lead of the pluggable terminal resistor 1 connect with output B B1 B to plug in...

Page 7: ...t RX 4 Input DTR 5 Ground 6 Output DSR 7 Input CTS 8 Output RTS 9 Output RING LED Indication The converters have three LED indicators RX data reception TX data transmission ST indication of the connec...

Page 8: ...90 720 8 E mail info adgt cz Table 4 Modes of indication ST RX TX No power Connection standby mode Power connection Resetting the device Factory settings reset ST LED indicator is on for 1 second and...

Page 9: ...parameter are available in section Configuring the converter through the web interface Attention When changing the used Ethernet standard in the network to which the converter is connected for exampl...

Page 10: ...ng Converter via Web Interface Setting up a local connection in Windows 10 After connecting converter to a PC or LAN hub it is necessary to configure the local connection Perform the following steps t...

Page 11: ...255 255 0 Accordingly the IP address in the connection settings must be the same as the address of the converter except for the last digits The last digits can be any from 0 to 254 except 0 and 254 a...

Page 12: ...rk settings and save changes using Submit button Table 5 Network settings Parameter Default value Possible values MAC address Use factory Use factory indicated on the sticker of the case Set manually...

Page 13: ...hite list of IP addresses of clients up to 5 addresses which are allowed to connect the converter when it operates in the Server mode Maximum number of incoming connections 2 2 1 Operation mode TCP cl...

Page 14: ...ect one end of the cable to the DB 9F connector of the converter connect the other end to the COM port on the PC If your computer does not have a COM port use a COM USB converter The COM port number o...

Page 15: ...interrupted by Stop button as well as saved into txt text file by Save to file button Reboot and factory reset Rebooting converter To reboot the device click Restart button in the Home menu Reset to...

Page 16: ...e message File is successfully uploaded Rebooting is in progress appears and you will be automatically redirected to the main page of the web interface Saving and Restoring the Configuration Settings...

Page 17: ...1 Table 8 List of commands for configuring the converter Command Description Note Feature2 help List of available commands R curr_gw Current network gateway R curr_ip Current IP address R curr_mac Cur...

Page 18: ...e Transmit Timeout from 1 to 10000 milliseconds R W rs232_world Data bits 0 8 bit 1 7 bit R W Settings of RS 485 RS 422 interface port 1 rs485_1_auth Authorization type 0 No authorization 1 ADGT autho...

Page 19: ...1 for Server mode The same way for Clients 2 5 R W rs485_2_mode Operation mode 0 Client 1 Server R W rs485_2_parity Parity 1 even 2 odd 0 no check R W rs485_2_port Port number R W rs485_2_remote Inte...

Reviews: