EDM Serial-to-Ethernet Converters
User Guide ver. 2.0 | 2021-09-01
Phone: +420 538 890 720
13
E-mail: [email protected]
4.
In the RS-232 Settings and RS-485/RS-422 Settings menues, configure parameters of the serial
ports in accordance with the settings of the connected equipment. For each port, select the
operating mode Client or Server and set its parameters.
Save changes using the Submit button.
Table 6. Configuring serial ports.
Parameter
Default value
Possible values
RS-232
RS-485/RS-422
State
Enabled
--------
Closed
in menu Home
Disabled port 1
and port 2
--------
Disabled
in menu Home
RS-232: disabled/enabled
RS-485: disabled port 1 and port 2/
enabled port 1/
enabled port 2/
enabled port 1 and port 2
RS-422: disabled port 1 and port 2/
enabled port RS-422
Operation mode “TCP-server” (default)
Port number
60001
RS-485(1): 60002
RS-422: 60002
RS-485(2): 60003
Number of TCP-port of server
List of allowed Client
IP-addresses (IP1-IP5)
0.0.0.0
(“White” list disabled,
all connections are allowed)
“White” list of IP-addresses of clients (
up to
5 addresses
), which are allowed to connect
the converter, when it operates in the
"Server" mode
Maximum number of
incoming connections
2
2, 1
Operation mode “TCP-client”
Port number
60001
RS-485(1): 60002
RS-422: 60002
RS-485(2): 60003
Port of TCP-server, to which the connection
will be made
Server IP address
0.0.0.0
(not specified)
IP-address of server, to which the
connection will be made
Authorization type
No authorization
No authorization, ADGT
Serial number
Each port has its own serial number
15-digit number for registration on the
server (when choosing an authorization
type ADGT)
Clearing the input buffer
on connection
not clear
not clear, clear
Maximum TCP Packet
Length
1024 byte
1 – 1024 byte
Force Transmit Timeout
10 ms
1 – 10000 milliseconds
Inactivity Time
30 sec
1 – 216000 seconds
Ping IP Address
0.0.0.0
(connection check disabled)
To enable connection check, specify the IP-
address to ping the connection (ICMP-echo)
Ping Request Frequency
30 sec
10 seconds – 43200 seconds
Flow Control
Disabled
Enabled, Disabled
Baud Rate
9600
600-115200 bit/sec
Data bits
8
8, 7
Parity
No check
Even, Odd, No check
Stop bits
1
1, 0.5, 1.5, 2