8-Troubleshooting 

 

 

If you comply with the instructions given in this manual, you should not have 

any major problem in enjoying your appliance. However, before requesting 

service, please check the following: 

 

 

 

1.

 

All the instructions given in this manual are complied with.  

2.

 

If there has been any recent change in the periphery that may have given rise to the problem. 

3.

 

If the problem falls into the following points. 

 

 

 

Problem (s) 

Possible Cause 

Correction 

The appliance is 

smoking 

 

Closed smoke damper regulation 

(when door open) 

 

Wet or green firewood. 

 

Dirty or clogged chimney. 

 

Check the baffle is moving freely 

when opening door. 

 

Use drier wood.  

 

Clean the chimney. 

Weak or 

inefficient burn 

 

Wet or green firewood. 

 

Dirty or clogged chimney. 

 

Insufficient firewood. 

 

Use dry wood.  

 

Clean the chimney. 

Very fast 

burning 

 

Low density firewood. 

 

Poorly adjusted door 

 

Filling cord consumed 

 

Load the stove with more dense 

firewood. 

 

Door readjustment  

 

Replacement of the cord  

The fire 

extinguishes 

 

Wet or green firewood. 

 

The appliance is not heated 

enough.  

 

Use drier wood. 

 

Leave the air lever open for 

longer to get a bed of coals 

before turning to low.  

Blower not 

working 

 

The thermostat's operating 

temperature has not been 

reached 

 

Power failure 

 

Load more firewood  

 

Check outlets and connections 

Dirty glass 

 

Wet or green firewood. 

 

Logs too close to or resting on the 

glass. 

 

Slightly open the air inlet control 

 

Use dry wood.  

 

Keep logs parallel to and away 

from glass. 

 

 

If the problem persists, please contact your retailer of the original purchase, to assist you to resolve the 

problem. 

 

Summary of Contents for 1000NMV-B

Page 1: ...orks Pty Ltd 57 Industrial Drive Braeside VIC 3195 TESTED IN ACCORDANCE WITH AS NZS 4013 2014 and AS NZS 2918 Please read this manual thoroughly before installing and starting your free standing appli...

Page 2: ...6 4 Installation Instructions 09 Chimney build out Version 10 Cabinetry Full Wall Build Install Zero Clearance 15 Ducting 20 Flue Outlet 23 5 Fan 26 6 Instructions for use 28 7 Cleaning and Maintenanc...

Page 3: ...om the sun and transform it into chemical energy The trapped energy eg in the form of wood pellets coal are called biomass fuels and can be converted into various forms electricity fuel or heat Biomas...

Page 4: ...ntilated Generally green wood should be left to season for two years Wood to Avoid Softwoods and low density wood This kind of firewood release a lot of heat but burn too quickly and projects embers a...

Page 5: ...ng 4 Primary convection outlet 5 Secondary convection outlet hot air distribution for ducting Inbuilt only 6 Smoke Outlet Flue collar 200mm 8 Crimped 7 Convection inlet Important o Please read this ma...

Page 6: ...page 10 15 See Page 10 15 Flue Diameter mm 200 200 Recommended Fuel Burn only Harwood Moisture 20 Electrical Specification W 36 V 220 240 Hz 50 60 Fan Settings Thermostat Low Manual High Model Dimens...

Page 7: ...nt to half the cross sectional area of the flue ie 160cm2 free air o Your appliance must be non permanently installed and easily accessible to ensure general maintenance chimney and equipment o The ap...

Page 8: ...F THIS APPLIANCE WHEN IT IS OPERATING o WARNING DO NOT STORE FUEL WITHIN THE HEATER INSTALLATION CLEARANCES o WARNING WHEN OPERATING THIS APPLIANCE AS AN OPEN FIRE USE A FIRE SCREEN o WARNING OPEN AIR...

Page 9: ...emove the legs The heater can then be carefully put into position The Heater will need to be inserted into the chimney build out before the construction is completed The Installations can be included...

Page 10: ...imney Build Out Install The build out is constructed with Skamotec 225 40mm sheets to Skamotec specifications the Installation and Clearance specifications are included in the Elevation drawings shown...

Page 11: ...11 The parts list required for the build out is shown...

Page 12: ...l Use Skamotec off cuts to space out from the wall The side walls continue to the rear wall enclosing the gap The minimum Ventilation area must be included below the base of the heater and below the c...

Page 13: ...13 STEP 3 STEP 4...

Page 14: ...14 STEP 5 STEP 6...

Page 15: ...mbustible materials to be built up to the side of the enclosure The build out is constructed with Skamotec 225 40mm sheets to Skamotec specifications the Installation and Clearance specifications are...

Page 16: ...16 The parts required for the build out is shown below...

Page 17: ...ort the heater leaving cut out for the heater fan to drop into The bench cut out is 560mm x 230mm from the rear of the base The assembly includes a 30mm air gap behind the rear sheet to combustible ma...

Page 18: ...is shown in the front as the dimensions at L If an alternative ventilation position is required ample free air flow must have access to the ventilation from outside the cavity The total vent area must...

Page 19: ...19 STEP 5 STEP 6...

Page 20: ...firebox and transferred to vents either on side of the Chimney breast via natural convection or via an air transfer kit with fan to other rooms From other supplier The blanking plates can be opened as...

Page 21: ...21 4 Fit a Ducting collar to the top of the fire box and fit ducting as required From other supplier...

Page 22: ...around the firebox opening due to heat Metal expansion could crack the Skamotec Ensure there is an expansion gap between the heater box and the Skamotec of 3 or 4mm A Frame can be fitted as follows t...

Page 23: ...t before tiling adhesive with suitable priming compound check with your board supplier 4 For more information check with your Skamotec supplier or Castworks Ensure there is a gap of 5mm between the he...

Page 24: ...ow The heater must have its own dedicated flue The active flue must be 8 for the entire length of the flue and always less than 45 degrees from the vertical Replacement room air from outside equivalen...

Page 25: ...25 External Requirements Refer to AS NZS 2918 2018 Note All external air vents ceiling penetrations must be bird rodent proofed with permanently fixed screens...

Page 26: ...It is made with a high temperature rated silicon outer case If additional cabling is required check with your electrician Mount the control switch into wall where required Do not mount in wall above t...

Page 27: ...ystem is well dimensioned ensuring proper drainage and that it complies with the Australian standards in force so that there is no undue smoke escape into the surrounding space Keep combustible and fl...

Page 28: ...scrunched up paper firelighters pine cones Then lay fine kindling around and on this base in such a way that they are interlocking and self supported thus allowing air to flow around them and without...

Page 29: ...with a good source of oxygen so that it does not run out and the air masses move in the right direction As for the air inlet grills it must be taken into account that they must be positioned in such...

Page 30: ...end of the winter season at which point the appliance will be out of use for some time thoroughly clean out the ash and residues inside it without using any abrasive products o With the aid of a vacu...

Page 31: ...or completely 3 Completely close the combustion air inlet and if possible to do safely cover the flue chimney outlet 4 The fire should be extinguished by itself due to lack of oxygen 5 In the absence...

Page 32: ...burn Wet or green firewood Dirty or clogged chimney Insufficient firewood Use dry wood Clean the chimney Very fast burning Low density firewood Poorly adjusted door Filling cord consumed Load the sto...

Page 33: ...d 2 The complaint must be presented and validated by one of our agents and endorsed by ADF 3 The installation use and maintenance conditions described in this manual have been strictly respected and n...

Page 34: ..._____________________________ Client Signature Note The Warranty is limited to the replacement repair by ADF or its agent of the components known to be defective and excludes any other type of coverag...

Page 35: ...Industrial Drive Braeside Vic 3195 Manufactured by A D F Lda Z I Relvinha Sarzedo A P 55 3304 909 Arganil Portugal 1000 TESTED BY AUSTRALIAN SOLID FUEL TESTING 3 GARDEN ST MORWELL VIC 3840 AUSTRALIA...

Page 36: ...36...

Reviews: