 ADFweb.com S.r.l.           

User Manual   

PROFINET Slave / LoRaWAN Gateway

 

 

Document code: MN67F33_ENG     Revision 1.000   Page 12 of 28

 

 

 

USE OF COMPOSITOR SW67F33: 

 

To  configure  the  Converter,  use  the  available  software  that  runs  with  Windows  called  SW67F33.  It  is  downloadable  on  the  site 
www.adfweb.com  and  its  operation  is  described  in  this  document.  The  software  works  with  MS  Windows  (XP,  Vista,  Seven,  8,  10,  11; 
32/64bit). 

 

 

 

When launching the SW67F33, the window below appears (Fig. 2). 
 

 

 

Note: 
    It is necessary to have installed .Net Framework 4. 

 

 

 
 

Figure 2: Main window for SW67F33 

Summary of Contents for HD67F33-B2 Series

Page 1: ...D67F16 BACnet Master www adfweb com Product HD67F17 BACnet Slave www adfweb com Product HD67F18 Ethernet www adfweb com Product HD67F19 CAN www adfweb com Product HD67F20 CANopen www adfweb com Produc...

Page 2: ...SUPPORT 28 RETURN POLICY 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product y...

Page 3: ...he device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and opera...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual PROFINET Slave LoRaWAN Gateway Document code MN67F33_ENG Revision 1 000 Page 4 of 28 EXAMPLE OF CONNECTION...

Page 5: ...trial Electronic Devices ADFweb com S r l User Manual PROFINET Slave LoRaWAN Gateway Document code MN67F33_ENG Revision 1 000 Page 5 of 28 CONNECTION SCHEME Figure 1 Connection scheme for HD67F33 B2 x...

Page 6: ...wer Supply Mountable on 35mm Rail DIN Wide power supply input range 12 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67F33 software on your PC in...

Page 7: ...3_ENG Revision 1 000 Page 7 of 28 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Page 8: ...ng of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is u...

Page 9: ...Hz update in progress 2 LoRaWAN communication yellow Blinks when a LoRaWAN message is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 PROFINET communication yellow Bli...

Page 10: ...services LoRaWAN network architecture is deployed in a star of stars topology in which gateways relay messages between end devices and a central network server The wireless communication takes advant...

Page 11: ...ramming the device The Ethernet connection must be made using Connector3 of HD67F33 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform...

Page 12: ...he Converter use the available software that runs with Windows called SW67F33 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS W...

Page 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable PROFINET Slave LoRaWAN Gateway Converter in order to configure another device in the s...

Page 14: ...nge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possib...

Page 15: ...ET Slave LoRaWAN Gateway Document code MN67F33_ENG Revision 1 000 Page 15 of 28 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insi...

Page 16: ...NS is checked DNS protocol is enabled In the field Primary DNS the IP Address of the primary DNS server is defined In the field Secondary DNS the IP Address of the secondary DNS server is defined The...

Page 17: ...is defined In the fields Gateway the default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the fi...

Page 18: ...AWAN Gateway Set Access window LORAWAN ACCESS By Pressing the LoRaWAN Access button from the main window for SW67F33 Fig 2 the window LoRaWAN Gateway Set Access appears Fig 4 This section is used to d...

Page 19: ...Key the Network session key for LoRaWAN connection is defined In the field Application Session Key the Application session key for LoRaWAN connection is defined In the field Application Key the Appli...

Page 20: ...WAN communication is defined In the field Start Test it is possible to define the starting byte to check offset inside the LoRaWAN message for recognizing specific LoRaWAN messages from end device opt...

Page 21: ...aWAN message to write from PROFINET is defined In the field Number Bytes the number of consecutive bytes to write from starting byte is PROFINET If the field On Change is checked the LoRaWAN message i...

Page 22: ...INET Slave LoRaWAN Gateway Document code MN67F33_ENG Revision 1 000 Page 22 of 28 PROFINET XML By pressing the PROFINET XML button it is possible to save the GSDML file for the PROFINET side of the co...

Page 23: ...thernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip...

Page 24: ...the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to progr...

Page 25: ...ectronic Devices ADFweb com S r l User Manual PROFINET Slave LoRaWAN Gateway Document code MN67F33_ENG Revision 1 000 Page 25 of 28 Figure 7 Mechanical dimensions scheme for HD67F33 B2 xxxMHz MECHANIC...

Page 26: ...on 868 868 MHz 915 915 MHz Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 2M 35mm DIN Rail mounting Device Family HD67F33 PROFINET Slave LoRaWAN Gateway Converter Order Code HD67F33...

Page 27: ...lection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Page 28: ...se do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Reviews: