background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

EtherCAT Slave / BACnet Master

 

 

Document code: MN67E05_ENG     Revision 1.000   Page 5 of 32

 

 

 

CONNECTION SCHEME: 

 

 

 
 
 
 

Figure 1a: Connection scheme for HD67E05-IP-A1

 

 

Summary of Contents for HD67E05-A1

Page 1: ...us TCP Slave www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 DeviceNet Master www adfweb com Produc...

Page 2: ...ARRANTIES AND TECHNICAL SUPPORT 32 RETURN POLICY 32 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated...

Page 3: ...e device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operat...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave BACnet Master Document code MN67E05_ENG Revision 1 000 Page 4 of 32 EXAMPLE OF CONNECTION...

Page 5: ...ustrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave BACnet Master Document code MN67E05_ENG Revision 1 000 Page 5 of 32 CONNECTION SCHEME Figure 1a Connection scheme for HD67E05 IP...

Page 6: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave BACnet Master Document code MN67E05_ENG Revision 1 000 Page 6 of 32 Figure 1b Connection scheme for HD67E05 MSTP A1...

Page 7: ...information between EtherCAT bus and BACnet bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compo...

Page 8: ...05_ENG Revision 1 000 Page 8 of 32 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Page 9: ...on the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is use...

Page 10: ...g Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 BACnet comm green It blinks when a BACnet response is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in pr...

Page 11: ...he standard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them while...

Page 12: ...IP communication The Ethernet connection must be made using Connector2 of HD67E05 xxx A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to confo...

Page 13: ...y to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield...

Page 14: ...at runs with Windows called SW67E05 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present...

Page 15: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Slave BACnet Master Converter in order to configure another device in the sam...

Page 16: ...e the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible...

Page 17: ...CAT Slave BACnet Master Document code MN67E05_ENG Revision 1 000 Page 17 of 32 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insid...

Page 18: ...it uses Ethernet BACnet MS TP it uses RS485 If selected BACnet IP the means of the fields for BACnet are In the fields IP ADDRESS the IP address of BACnet IP side of the converter is defined In the fi...

Page 19: ...address for master nodes The value shall be less than or equal to 127 The field Max Info Frames specifies the maximum number of information frames the node may send before it must pass the token In t...

Page 20: ...the EtherCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT variab...

Page 21: ...iable is enabled In the field Type the data format of the EtherCAT variable is defined In the field Lenght the dimension of the EtherCAT variable is defined In the field Name the name of the EtherCAT...

Page 22: ...ct Type the object to be read is defined In the field Instance the instance number of the object is defined In the field Property the property to be read is defined In the field NByte the number of by...

Page 23: ...at the Master waits before resetting the data for the specific requests is defined In the field Position the starting byte of the internal memory array where mapping the data read is defined The field...

Page 24: ...yte the number of bytes of the BACnet object is defined By checking the field En Dest it is possible to enable the Destination Network D Net Destination Length D Len and Destination Address D Adr Thes...

Page 25: ...starting byte of the internal memory array from which taking the data to write is defined The field Start Bit is used for the Binary Output BACnet objects It is possible to select the bit in the byte...

Page 26: ...hernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1...

Page 27: ...he program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to progra...

Page 28: ...Electronic Devices ADFweb com S r l User Manual EtherCAT Slave BACnet Master Document code MN67E05_ENG Revision 1 000 Page 28 of 32 MECHANICAL DIMENSIONS Figure 8a Mechanical dimensions scheme for HD6...

Page 29: ...ndustrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave BACnet Master Document code MN67E05_ENG Revision 1 000 Page 29 of 32 Figure 8b Mechanical dimensions scheme for HD67E05 MSTP A1...

Page 30: ...le 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting BACnet port IP BACnet IP MSTP BACnet MS TP Device Family HD67E05 EtherCAT Slave BACnet Master Converter Order Code HD67E05 IP A1 EtherC...

Page 31: ...ection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the r...

Page 32: ...e do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...