POWER SUPPLY FOR ACTUATORS UA (for IO-Link Class B): 
 

The Power Supply for actuators UA is used to provide an additional power supply and it is available just for Class B version. 
The output voltage is typically to 24 V DC, but it can arrive up to 35 V DC. The maximum current that can pass is 1 A. 

Summary of Contents for HD67983-B2-IA

Page 1: ...dbus TCP Master www adfweb com Product HD67964 Modbus TCP Slave www adfweb com Product HD67965 BACnet Master www adfweb com Product HD67966 BACnet Slave www adfweb com Product HD67967 CAN www adfweb c...

Page 2: ...WARRANTIES AND TECHNICAL SUPPORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated...

Page 3: ...e device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operat...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual IO Link Slave PROFINET Master Document code MN67983_ENG Revision 1 000 Page 4 of 30 EXAMPLE OF CONNECTION...

Page 5: ...ustrial Electronic Devices ADFweb com S r l User Manual IO Link Slave PROFINET Master Document code MN67983_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1a Connection scheme for HD67983 B2...

Page 6: ...Industrial Electronic Devices ADFweb com S r l User Manual IO Link Slave PROFINET Master Document code MN67983_ENG Revision 1 000 Page 6 of 30 Figure 1b Connection scheme for HD67983 B2 IB...

Page 7: ...DIN Two directional information between PROFINET and IO Link Possibility to have Class A or Class B version in relation to the order code Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You...

Page 8: ...ion which uses standard unshielded cables IO Link sends all the sensor and actuator signals to the controller and in turn carries controller data to the sensor actuator level with revolutionary conseq...

Page 9: ...User Manual IO Link Slave PROFINET Master Document code MN67983_ENG Revision 1 000 Page 9 of 30 IO LINK CLASS B IO Link Class B devices uses 5 pins on connectors and they allow to provide an external...

Page 10: ...vision 1 000 Page 10 of 30 POWER SUPPLY FOR ACTUATORS UA for IO Link Class B The Power Supply for actuators UA is used to provide an additional power supply and it is available just for Class B versio...

Page 11: ...ng of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is u...

Page 12: ...tion OFF IO Link power supply not present ON IO Link power supply OK but no communication Blinking IO Link powered and communicating Blinks quickly Boot state Blinks very slowly 0 5Hz update in progre...

Page 13: ...INET communication The Ethernet connection must be made using Connector3 of HD67983 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform...

Page 14: ...he Converter use the available software that runs with Windows called SW67983 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS W...

Page 15: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable IO Link Slave PROFINET Master Converter in order to configure another device in the sa...

Page 16: ...ge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possibl...

Page 17: ...k Slave PROFINET Master Document code MN67983_ENG Revision 1 000 Page 17 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insid...

Page 18: ...DNS is checked DNS protocol is enabled In the field Primary DNS the IP Address of the primary DNS server is defined In the field Secondary DNS the IP Address of the secondary DNS server is defined The...

Page 19: ...of the fields are If the field Enable is checked the IO Link variable is enabled In the field Name the name of the IO Link variable is defined In the field Lenght the dimension in bit of the variable...

Page 20: ...t the gradient of the variable is defined In the field Offset the offset of the variable is defined In the field Unit Code the unit for the variable is defined In the field Default Value the default v...

Page 21: ...ROFINET ACCESS By Pressing the PROFINET Access button from the main window for SW67983 Fig 2 the window Definition of PROFINET Devices Present in Network appears Fig 5 This section is used to define t...

Page 22: ...T slave is defined If the field Automatic new session when StationProblemIndicator is Active is checked the converter opens a new communication session when an error is present in the slave station In...

Page 23: ...g 6 In the main table it is possible to import the Modules of the PROFINET device in use In the properties below it is possible to set the parameters of the slave These options depends on the slave in...

Page 24: ...DFweb com S r l User Manual IO Link Slave PROFINET Master Document code MN67983_ENG Revision 1 000 Page 24 of 30 IO LINK IODD FILE By pressing the IO LINK IODD FILE button it is possible to save the I...

Page 25: ...thernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip...

Page 26: ...program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 10 or 11 make sure that you have the administrator privileges In case you have to progra...

Page 27: ...Electronic Devices ADFweb com S r l User Manual IO Link Slave PROFINET Master Document code MN67983_ENG Revision 1 000 Page 27 of 30 Figure 9 Mechanical dimensions scheme for HD67983 B2 Ix MECHANICAL...

Page 28: ...formed by a valid combination of the following HD67983 B 2 Ix IO Link Class A Class A B Class B Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 3M 35mm DIN Rail mounting Device Family...

Page 29: ...ection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the r...

Page 30: ...se do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Reviews: