background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

CAN from/to Modbus Slave 

 

Document code: MN67412_ENG     Revision 1.000    Page 2 of 25 

 

 

INDEX: 

 

 

 

Page 

INDEX 

UPDATED DOCUMENTATION 

REVISION LIST 

WARNING 

TRADEMARKS 

CONNECTION SCHEME 

POWER SUPPLY 

RS485 

CAN 

CHARACTERISTICS 

CONFIGURATION 

USE OF COMPOSITOR SW67412 

NEW PROJECT / OPEN PROJECT 

GENERAL PARAMETER 

10 

RECEIVE COB 

11 

DEFINE COB 

12 

TRANSMITCON 

13 

DEFINE COB 

14 

UPDATE DEVICE 

15 

MECHANICAL DIMENSIONS 

16 

ORDERING INFORMATIONS 

20 

ACCESSORIES 

24 

WARRANTIES AND TECHNICAL SUPPORT 

25 

RETURN POLICY 

25 

PRODUCTS AND RELATED DOCUMENTS 

25 

UPDATED DOCUMENTATION: 

 

Dear  customer,  we  thank  you  for  your  attention  and  we  remind  you  that  you 
need to check that the following document is: 

 

Updated 

 

Related to the product you own

 

 
To obtain the most recently updated document, note the “document code” that  
appears at the top right-hand corner of each page of this document. 
 
 With  this  “Document  Code”  go  to  web  page  www.adfweb.com/download/  and 
search for the corresponding code on the page. Click on the proper “Document 
Code” and download the updates. 
 
To  obtain  the  updated  documentation  for  the  product  that  you  own,  note  the 
“Document Code” (Abbreviated written "Doc. Code" on the label on the product) 
and download the updated from our web site www.adfweb.com/download/  

 

 

REVISION LIST: 

 

Revision 

Date 

Author 

Chapter 

Description 

1.000 

14/11/2011 

Fl 

All 

First release version 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

WARNING: 

 

ADFweb.com reserves the right to change information in this manual about our 
product without warning. 
ADFweb.com is not responsible for any error this manual may contain. 

 

 

TRADEMARKS: 

 

All trademarks mentioned in this document belong to their respective owners.

 

Summary of Contents for HD67412-E Series

Page 1: ...Resined optionally Wide supply input range Triple isolation Industrial temperature range 40 C 105 C 22 F 158 F Similiar Products For other Gateways Bridges CAN from to Modbus See also the following l...

Page 2: ...to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each pa...

Page 3: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN from to Modbus Slave Document code MN67412_ENG Revision 1 000 Page 3 of 25 CONNECTION SCHEME Figure 1 1 Con...

Page 4: ...ices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN from to Modbus Slave Document code MN67412_ENG Revision 1 000 Page 4 of 25 Figure 1 2 Connection s...

Page 5: ...of 25 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD67412 Exx xxx 8V 26V 10V 40V Consumption at 24V D...

Page 6: ...ne with a 220 resistor in the HD67412 Exx xxx is made internally of the device when the order is performed If the device have the RS485 terminated the code is the follow HD67412 Exx xYx otherwise is t...

Page 7: ...HD67412 E7x xxx device must be made with a AMP SuperSeal 1 5 Male connector The pinout of Female connector of the board is at right side of the page The termination of CAN line with a 120 resistor in...

Page 8: ...E7x xxx is furnished with 10 cm cable length CONFIGURATION The CAN from to Modbus Slave Gateway allows a CAN network to communicate with a Modbus network You need Compositor SW67412 software on your P...

Page 9: ...To clone the configurations of a Programmable CAN from to Modbus Slave Gateway in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To cl...

Page 10: ...0A or CAN Bus 2 0B TimeOut Data is the maximum time that the device attends for the CAN Frame In the field Modbus Register insert the value of Modbus register which contains the number 1 if a CAN fram...

Page 11: ...12 Fig 2 the window Receive CAN Frame appears Fig 4 A user who has to read a CANbus frame from CANbus to Modbus needs to insert the coordinates of the CANbus frame in order to be transmitted in the fi...

Page 12: ...the field MODBUS there are the modbus words defined for that COB ID Frame In the field Index MODBUS there is the address that contain the Modbus word In the field Selecet Frame Byte you select the po...

Page 13: ...2 Fig 2 the window Transmit CAN Frame appears Fig 6 A user who has to write a CANbus frame from Modbus to CANbus needs to insert the coordinates of the CANbus frame in order to be transmitted in the f...

Page 14: ...the list In the field MODBUS there are the Modbus words defined for that COB ID Frame In the field Index MODBUS there is the address that contain the Modbus word In the field Seleceted Frame Byte you...

Page 15: ...ate of CAN is known select it in the field Select the BaudRate of CAN otherwise you have to select Search Baudrate Press the Next button Select which operations you want to do You can select only Firm...

Page 16: ...lectronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN from to Modbus Slave Document code MN67412_ENG Revision 1 000 Page 16 of 25 MECHANICA...

Page 17: ...trial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN from to Modbus Slave Document code MN67412_ENG Revision 1 000 Page 17 of 25 Ty...

Page 18: ...trial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN from to Modbus Slave Document code MN67412_ENG Revision 1 000 Page 18 of 25 Ty...

Page 19: ...trial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN from to Modbus Slave Document code MN67412_ENG Revision 1 000 Page 19 of 25 Ty...

Page 20: ...MATIONS The ordering part number is formed by a valid combination of the following HD67412 E y z s d f Fixing lugs A Type 1 B Type 2 C Type 3 RS485 Termination Y Terminated with 220 N Not terminated C...

Page 21: ...minated CAN not terminated and fixing lugs Type C Order Code HD67412 E4V YNA CAN from to Modbus Slave with MiniFit connectors electronic board varnished RS485 not terminated CAN terminated and fixing...

Page 22: ...ated and fixing lugs Type B Order Code HD67412 E4R YNC CAN from to Modbus Slave with MiniFit connectors electronic board resined RS485 not terminated CAN terminated and fixing lugs Type C Order Code H...

Page 23: ...N terminated and fixing lugs Type A Order Code HD67412 E7V YYB CAN from to Modbus Slave with SuperSeal 1 5 connectors electronic board varnished RS485 terminated CAN terminated and fixing lugs Type B...

Page 24: ...s Type B Order Code HD67412 E7R YNC CAN from to Modbus Slave with SuperSeal 1 5 connectors electronic board resined RS485 not terminated CAN terminated and fixing lugs Type C Order Code HD67412 E7R YY...

Page 25: ...uest you need to provide detailed information about the problem 2 Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accept...

Reviews: