SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1
36
Page
of 45
GB
2.5. Configuration the SIGFOX SENSORS unit (digital input)
In this configuration, the device send a data frame only when a state is changing on at least one dry contact input.
The SIGFOX SENSORS is configured via the combination of switches. The following settings can be changed
•
Transmission interval
•
Inputs activation (sensors 1 and 2)
•
The type of sensor connected
If only one of two ways is configured in dry contact, both inputs will works in dry contact
CONFIGURATION TABLE:
Parameter
Value
SW1
SW2
SW3
SW4
SW5
SW6
Debounce Time
(Only Available
on Digital Input Mode)
100ms
OFF
OFF
1s
OFF
ON
10s
ON
OFF
1 minute
ON
ON
Activation of sensor
inputs
Sensors 1&2 inactives
OFF
OFF
Sensor 1 active
ON
OFF
Sensor 2 active
OFF
ON
Sensor 1&2 actives
ON
ON
Sensor type
Sensor 1&2 Dry Contact
ON
ON
PLEASE NOTE
: You must set your switches before activating the meters. Once the fraud wire for each of the meters has been installed and the
SigFox SENSORS has been started via magnet, the configuration with the switchs can no longer be possible.
If the configuration has any difference between the switchs and the product register value, the consistency error bit will be set to on in the
frame. This consistency verification is carried out every minute.
2.6. Closing the casing
Once steps 3.2, 3.3 and 3.4 have been completed, you can close the SIGFOX SENSORS’s case.
Procedure:
• Make sure the seal is installed correctly on the case plate.
Seal
Summary of Contents for SIGFOX SENSORS
Page 4: ...SIGFOX SENSORS Mode d emploi User guide version V2 1 1 4 Page of 45 FR FRANCAIS...
Page 6: ...SIGFOX SENSORS Mode d emploi User guide version V2 1 1 6 Page of 45 FR...
Page 25: ...SIGFOX SENSORS Mode d emploi User guide version V2 1 1 25 Page of 45 GB ENGLISH...
Page 27: ...SIGFOX SENSORS Mode d emploi User guide version V2 1 1 27 Page of 45 GB...