sigfox RC2 Pulse - Guide utilisateur / User guide version V1.0.0
78
Page
of 99
FR
0
1
2 - 3
4 - 5
Code
Status
PAYLOAD
0x12
Cf Status
S330
S331
0x12
0xA3
0x0003
0x0005
Description of the frame:
• Bytes 2 and 3 : register 330, number of daily periods under leak threshold (channel A)
• Bytes 4 and 5 : register 331, number of daily periods under leak threshold (channel B)
In the example in grey this gives:
• Bytes 2 and 3 : S330=0x0003, number of daily periods under leak threshold for channel A is set to 3
• Bytes 4 and 5 : S331=0x0005, number of daily periods under leak threshold for channel B is set to 5
4.1.3 Frame of information on the network configuration
Following reception of a downlink frame with the code 0x02 or on switching to the operating mode (from the Park or Command Mode), the
next frame (0x20) representing the network confguration of the product is transmitted:
0
1
2
Code
Status
PAYLOAD
0x20
Cf Status
S202
0x20
0xA3
0x2A
Its size is of 3 bytes.
Description of the frame:
• Byte 2 : register S202 : network area and number of repetitions
In the example in grey this gives:
• Byte 2=0x2A: the network area is RC2 and the number of repetitions is 2
4.1.4 Keep Alive frame
This frame (0x30) is trasmitted 24 heures after the startup of the application or after the transmission of the previous Keep Alive frame. In TEST
mode, this frame is transmitted every 5 minutes.
0
1
2
3 - 4
5 - 6
7 - 8
9 - 10
Code
Status
PAYLOAD
0x30
Cf Status
Alarms
Max flow - chan-
nel A
Max flow - chan-
nel B
Min flow - chan-
nel A
Min flow - chan-
nel B
0x30
0xA3
0x19
0x310A
0x12C4
0x0010
0x0000
Its size is of 11 bytes.
Description de la trame :
• Byte 2 : Alarms state (bit to 1 if the alarm is activated else 0) :
• Bit 0 – Exceeding flow on channel A
• Bit 1 – Exceeding flow on channel B
• Bit 2 – Tamper detected on channel A
• Bit 3 – Tamper detected on channel B
• Bit 4 – Leak detected on channel A
• Bit 5 – Leak detected on channel B
• Bit 6/7 – Reserved
• Bytes 3 to 4 : maximum measured flow on channel A within the last 24 hours.
• Bytes 5 to 6 : maximum measured flow on channel B within the last 24 hours.
• Bytes 7 to 8 : minimum measured flow on channel A within the last 24 hours.
• Bytes 9 to 10 : minimum measured flow on channel B within the last 24 hours.