EN
sigfox RC2 Pulse - Guide utilisateur / User guide version V1.0.0
74
Page
of 99
FR
323
4
Current value of meter -
channel A
Decimal
Default value: 0
Min/max : 0 to (2
32-1
)
Unit : number of pulses
In COMMAND mode, it is possible to write a new value in this
register (for example an initialization value, an adjustment
value ...).
324
4
Current value of meter -
channel B
Decimal
Default value: 0
Min/max : 0 to (2
32-1
)
Unit : number of pulses
In COMMAND mode, it is possible to write a new value in this
register (for example an initialization value, an adjustment
value ...).
325
2
Flow calculation period
(channels A and B)
Decimal
Default value: 60
Min/max : 1 to 1440
Unit :
x 1min if S306=1
x 20s if S306=2
326
2
Flow threshold (channel A)
Decimal
Default value :0 (deactivated)
Min/max : 0 to 65535
Unit: pulses per hour
327
2
Flow threshold (channel B)
Decimal
Default value :0 (deactivated)
Min/max : 0 to 65535
Unit: pulses per hour
328
2
Leak threshold (channel A)
Decimal
Default value: 0
Min/max : 0 to 65535
Unit : pulses per hour
329
2
Leak threshold (channel B)
Decimal
Default value: 0
Min/max : 0 to 65535
Unit : pulses per hour
330
2
Number of daily periods
under the leak threshold
(channel A)
Decimal
Default value: 0 (deactivated)
Min/max : 0 to 1440
Unit : none
The multiplication of this register by the period of flow measu-
rement must be less than 24 hours otherwise the product will
be perpetually in alarm.
331
2
Number of daily periods
under the leak threshold
(channel B)
Decimal
Default value: 0 (deactivated)
Min/max : 0 to 1440
Unit : none
The multiplication of this register by the period of flow measu-
rement must be less than 24 hours otherwise the product will
be perpetually in alarm.
332
1
Scan period for Channel A
tamper input
Decimal
Default: 2
Min/Max: 1 to 255
Unit: x10 seconds
333
1
Tamper detection threshold
channel A
Decimal
Default: 3
Min/Max: 1 to 255
Unit: none
Number of positive scans of A-channel tamper before trigge-
ring the tamper alarm
334
1
Scan period for Channel B
tamper input
Decimal
Default: 2
Min/Max: 1 to 255
Unit: x10 seconds
335
1
Tamper detection threshold
channel B
Decimal
Default: 3
Min/Max: 1 to 255
Unit: none
Number of positive scans of B-channel tamper before trigge-
ring the tamper alarm