EN
sigfox RC2 Pulse - Guide utilisateur / User guide version V1.0.0
67
Page
of 99
FR
A complete list of the registers can be found in paragraph 3.4.
Example :
Register
Value encoding
Value
Result
S320
Hexadecimal
0x39
Channel A :
• Activated
•
Meter other than gas
•
Tamper input activated
Channel B :
• Activated
•
Gas meter
•
Tamper input disabled
S321
Hexadecimal
0x02
Channels A and B : historical mode with backup of the counters every hour
and transmission every 24h so 24 values per counter
S322
Hexadecimal
0x57
Debounce :
•
Channel A = 500ms
•
Channel B = 100ms
S325
Decimal
60
Flow calculation period (channels A and B) = 60min
S328
Decimal
10
Leak threshold (channel A) = 10 pulses par hour
S329
Decimal
0
Leak threshold (channel B) = 0 pulse par hour
S330
Décimal
3
Daily periods number under the leak threshold (channel A) = 3
S331
Decimal
5
Daily periods number under the leak threshold (channel B) = 5
In this example, all the periods during which the flow rate on the channel A is less than 10 pulses / hour are considered as periods of zero flow.
If the total daily number of zero flow periods is less than 3 then it is considered that there is a leak on the channel A.
2.2.7 TEST mode
This mode allows the user to perform tests of the product more quickly by reducing the time scales of the production mode and modifying the
behaviour of the LEDs.
It is obtained by positioning register S306 at the value 2 in the COMMAND mode. Once out of the command mode, the product returns to the
previously defined application behaviour but with the following changes:
• Register S300: the periodicity of the Keep Alive is expressed in groups of 5 minutes instead of 24 hours.
• Registre S301 : the periodicity of the sending of data (periodic mode) is expressed in groups of twenty seconds instead of tens of minutes.
Hence in test mode when register 301 = 1, the Keep Alive frame is no longer sent every 10min but every 20 seconds.
• Register S325 : the flow calculation period (channels A and B) is expressed in twenty seconds slots instead of minutes. So in TEST mode
when the register 325 is set to 60, the flow calculation period (channels A and B) is 60x20s=1200s (so 20min) instead of 60 minutes.
• The LEDS also have a different behaviour, allowing a visual feedback to the user in the event of transmission and reception of frames (see
paragraph 2.3 for more details).
A complete list of the registers can be found in paragraph 3.4.
Register Coding the value
Value
Result
S306
Decimal
2
The product is in TEST mode
S300
Decimal
--
The Keep Alive frame is sent every 5 minutes
S301
Decimal
1
Periodic mode with a period of 1x20 = 20s
S325
Decimal
60
Flow calculation period (channels A and B) is 60x20s=1200s ie 20
minutes