1.3. Technical specifications
Radio
Communication
sigfox protocol and DBPSK sigfox
Radio Rate
Variable (SF12/125kHz (~183 bps) to FSK (~50kbps)
Frequency
ISM band 863-870MHz
RF Power
14dBm (25mW)
Sensitivity
Down to -140 dBm in SF12/CR4
Range (Open)
Up to 15km
Standards met
EN 300-220, EN 301-489, EN 60950
Network area
RC1
Supply
Connector
Micro-USB - 5V - 500mA
Battery
Lithium-Ion Polymer 3.7V 2Ah 7.4Wh
Operational
Device configuration
Via AT commands
(see relevant chapter to find a full list of available AT commands)
Serial rate
115.2 kbps
Parity
None
Amount of data
8
Stop bit
1
Functioning temperature
-30°C / +70°C
1.4. Charging the FTD
The device is equipped with a rechargeable battery. Once the device has been connected to a USB charger or the USB socket of a computer, it
will start to charge automatically; even if the ON/OFF communicator is set to OFF (this functions in exactly the same way as a mobile phone).
The device can be used while it is charging. During charging, the charge indicator will be red. When the device is fully charged, the indicator will
turn green.
Figure 1 : Device charging
Figure 2 : Device is fully charged