3.6. Starting up the product using a magnet
Once the product has been configured and its assembly has been finalised, the product is ready to be started up.
The start-up is carried out using a magnet which you place on the upper part of the product (cf. the diagram below). The magnet must be held
in position for at least 6 seconds so as to confirm the start-up of the product.
Once the AMR Sensors unit validates its start-up, it will immediately transmit 2 data frames and two log frames.
The AMR Sensor unit does not have any external status LED. To make sure that the product starts up properly, we advise you to place a data
receiver in the vicinity of your product before starting it up using the magnet. You will thus be able to receive the 2 start-up frames and confirm
the smooth running of your product.
•
Finish the assembly by locking the packing gland’s nut in position
Packing gland nut
Position of the magnet for
starting up the product
NB 1:
Once the AMR Sensors unit has started up, it cannot be switched off.
NB 2:
If the magnet is placed on it a second time, the AMR Sensors unit will switch to Configuration mode. A 4-minute period will begin, during
which the product cannot transmit. Once these 4 minutes have elapsed, if no parameter has been modified, the product will switch back to
Operations mode. If a parameter has been modified, the product will switch back
to Standby mode and must be relaunched (cf. Chapter 3.4)