Chapter 3 - SmartController Operation
50
Adept SmartController User’s Guide, Rev. E
10,23
MANUAL/AUTO indication CH 2
Contacts are closed in
AUTOMATIC mode
11,12,
13,24,25
No connection
Table 3-8. Contacts Provided by the XFP Connector
Pin
Pairs
Description
Comments
Voltage-Free Contacts Provided by Customer
1,9
Front Panel E-Stop CH 1
N/C contacts
2,10
Front Panel E-Stop CH 2
N/C contacts
3,11
Remote MANUAL/AUTOMATIC switch CH 1.
MANUAL = Open AUTOMATIC = Closed
4,12
Remote MANUAL/AUTOMATIC switch CH 2.
MANUAL = Open AUTOMATIC = Closed
6,14
Remote High Power on/off momentary PB
Used to enable High Power
Nonvoltage-Free Contacts
5,13
Adept Supplied 5 VDC and GND for High Power
On/Off Switch Lamp
Use with Remote High
Power On/Off switch above.
7,15
SmartController system 5V power on LED, 5V, 20mA
8
No connection
See
Figure 3-6 on page 54
for a schematic diagram of the Adept Front Panel.
Table 3-7. Contacts Provided by the XUSR Connector (Continued)
Pin
Pairs
Description
Comments
Shorted if
NOT Used
XUSR
Pin 1
Pin 13
Pin 14
Pin 25
Pin 1
Pin 8
Pin 9
Pin 15
XFP
Summary of Contents for SmartController CS
Page 2: ......
Page 36: ...Chapter 2 SmartController Installation 36 Adept SmartController User s Guide Rev E...
Page 84: ...Chapter 4 AdeptVision sAVI Option 84 Adept SmartController User s Guide Rev E...
Page 155: ......
Page 156: ...3011 Triad Drive Livermore CA 94551 925 245 3400 P N 00356 00100 Rev E...