2
1.3 Remember to measure resistance
The resistance should be measured between the two conductors, blue and brown. Compare this
resistance reading to the resistance specified in the Product Selection Table. The value should be
within
-5% to +10%. If you get a different reading, contact Adept at 01394 593110.
Also, measure the resistance between the blue, brown and yellow green ground wire. Both should
read infinity. If you get a different reading, contact Adept at 01394 593110.
Please refer to “5 Commissioning” for instructions on how to measure the resistance.
Important: measure the resistance three times during the installation process
Remember to always measure, verify and record the actual resistance throughout the
installation process (out of the box, after installation
and after installation of wood floor).
1.4 Lifetime Warranty
From the date of purchase, Adept warrants that the Foil Heating Mat heating cable is free from
defects in material, design and workmanship. The extended warranty is only valid if the warranty
certificate has been properly completed and mailed, and the installation is in accordance with the
installation instructions.
2 Foil Heating Mat Systems
2.1 Foil Heating Mat Specifications
2.2 Foil Heating Mat typical installations and applications
Warning
Consult the manufacturer for information on special installation requirements for wood, laminate
and vinyl or linoleum flooring.
Important
· Read the instructions carefully before installing Foil Heating Mat system.
Cable Construction:
Twin conductor
Rated Voltage:
230V
Output:
140W/m
2
Cable spacing:
50mm
Cable Diameter:
1.0mm
Conductor Insulation:
Fluorpolymer
Max. Ambient Temp.:
3
0°C(
85
°F)
Min. Installation Temp.:
5
°C(
40
°F)
Cold lead
2-wire plus ground braid; 2.5m length