6 Troubleshooting
Symptom
Probable Causes
Corrective Action
Floor doesn’t heat
No voltage.
Circuit breaker tripped.
Ground-fault tripped in
the thermostat.
Thermostat not turned
on.
Cable not connected to
Thermostat.
Floor temperature sensor
not connected.
Faulty sensor.
Check circuit breaker.
Ensure that there are not too many mats or other
appliances connected on the same circuit. The
Foil Heating Mat may require a dedicated circuit.
See the Product Selection Table of this manual.
Refer to Thermostat Installation and Operation
Manual.
Refer to Section 4 of this manual, and the
Thermostat Installation and Operation Manual.
Refer to Thermostat Installation and Operation
Manual.
Refer to Thermostat Installation and Operation
Manual.
Contact Adept at 01394 593110.
Floor warm all the time
Clock not set correctly.
Refer to Thermostat Installation and Operation
Manual.
Floor not warm enough
Thermostat setting not
set correctly.
Refer to Thermostat Installation and Operation
Manual.
Installation instructions
not available
Contact Adept (Tel: 01394 593110)