INCOMING
PHONE
LINE
TO HANDSET
PHONE
LINE
WARNING:
TO PREVENT
RISK OF
SHOCK
DISCONNECT
TELEPHONE
LINE AT TELECOM
JACK BEFORE
SERVICING
THIS UNIT.
LOCAL SOUNDER
DISABLE JUMPER
CUT = DISABLE
WEEKLY TESTING IS
REQUIRED TO ENSURE
PROPER OPERATION
OF THIS SYSTEM
ALL OUTPUT
CIRCUITS
ARE POWER
LIMITED.
PREMISES
TELEPHONE
2k OHMS
EOLR
1
2
3
4
8
6
5
11
7
10
12
15
16
13
14
PHONE
ZONE
AAV
TRIGGER
SOUNDERS
PLCD
AC
PLUG-IN
TRANSFORMER
9VAC, 15VA
EARTH
GROUND
EARTH
GROUND
HARD
WIRED
ZONE
INCOMING
TELEPHONE
LINE
RING
TIP
RING
TIP
( )
( )
(+)
(+)
( )
(+)
TO 24HR 110VAC
UNSWITCHED
OUTLET
PIEZO
6-14VDC
120mA max.
(e.g. WAVE2EX)
6-14VDC
30mA max.
DATA
OUT
SYNC
IN
PO
WERLINE
CARRIER DEVICES
TRIGGER SIGNAL (NEG)
RJ11
8
POSITION
JACK
AC
AC
SYNC
COM
DATA
9
LYNXR24 IS EQUIPPED WITH AN INTEGRAL
RECHARGABLE BATTERY PACK P/N LYNXRCHKIT-HC.
REPLACE EVERY FOUR YEARS.
LYNXR IS EQUIPPED WITH AN INTEGRAL
RECHARGABLE BATTERY PACK P/N LYNXRCHKIT-SC.
REPLACE EVERY FOUR YEARS.
BELL
01000-015-V0
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE
HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING
INTERFERENCE THAT MAY CAUSE UNDESIRED
OPERATION.
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE PROTECTION
ASSOCIATION'S STANDARD 72, CHAPTER 2 (NATIONAL
FIRE PROTECTION ASSOC., BATTERYMARCH PARK,
QUINICY, MA 02269).
PRINTED INFORMATION DESCRIBING PROPER
INSTALLATION, EVACUATION PLANNING AND
REPAIR SERVICE IS TO BE PROVIDED WITH THIS
EQUIPMENT.
1332X10 ONLY
CONNECTIONS
FCC ID: CFS8DLLYNX COMPLIES WITH FCC RULES,
PART 68 FCC REGISTRATION No. 5GBUSA-25623-AL-E
RINGER EQUIVALENCE: 0.6B
1332/1332X10/1332CN
CONNECTIONS
NOTE
USE ONLY
1332/1332X10
OR 1332CN
TRANSFORMERS
PROVIDED
LYNXR/LYNXR24 WIRING CONNECTIONS
System Programming
Step
Action
1.
Set a programming default as follows:
a.
Enter Programming mode: Installer Code + 8 0 0.
b.
Press *97, then press a number 1-4 to select a default table from the tables listed on page 1.
2.
Program the variable data fields as follows:
a.
RF House ID - Press *24, then enter the desired 2-digit RF House ID for wireless keypads.
b.
PABX Access Code (if used) - Press *40, then enter up to 6 digits. If fewer than 6 digits are used, press [*] to
end the field and advance to the next field.
c.
Primary Phone Number - Press *41, then enter the primary phone number, up to 20 digits. If fewer than 20
digits are used, press [*] to end the field and advance to the next field.
d.
Secondary Phone Number (if used ) - Press *42, then enter the secondary phone number, up to 24 digits. If
fewer than 24 digits are used, press [*] to end the field and advance to the next field.
e.
Secondary Account Number (if used) - Press *44, then enter the secondary account number. If only 3 digits
are used, press [*] to end the field and advance to the next field.
f.
Pager Characters - Press *88 if using Default Table 2 or 4, then enter up to 16 digits which may be required
by your pager service (e.g. account number, PIN, etc.). If fewer than 16 digits are used, press [*] to end the
field and advance to the next field.
g.
Download Phone Number - Press *94, then enter the downloading computer phone number, up to 20 digits.
If fewer than 20 digits are used, press [*] to end the field.
-3-