Step
Action
4.
Set RF House ID in the wireless keypads as follows:
a.
5827 wireless keypad - Set the keypad’s DIP switches to the RF House ID programmed in field *24.
b.
5804BD button key or 5827BD keypad - Set the RF House ID per its instructions.
c.
Powerline Carrier Devices - Set their House ID to “A,” (programmed as “0”) or use field *25 to change the ID to avoid
conflicts with existing installations.
5.
Set the Real-Time Clock as follows:
a.
Enter time/date setting mode by entering the User Code + FU [63].
b.
The hour prompt is displayed. Enter the correct hour, then press [*] to accept and advance.
c.
For each subsequent prompt, enter the correct value, then press [*].
d.
The system will exit this mode automatically after entering the year, or if no keys are pressed for 1 minute.
6.
Test the system as follows:
a.
After installation and programming, enter Installer Code + TEST.
b.
To exit Test mode, enter Installer Code + OFF.
7.
Assign desired User Codes by following the procedures on the next page and in the User Guide. Show the user how to perform
the various system functions.
8.
Perform site-initiated downloader session (to load central station ID) by Installer Code + [#] + [1].
5800 Series Transmitter Loop Numbers: The following illustration shows the compatible transmitters and their associated
input types and loop designations.
LOOP 1
5806/5807/5808/5808LST
ENROLL AS "RF"
LOOP 1
5809
ENROLL AS "RF"
5 8 1 8
ENROLL AS "RF"
LOOP 1
5 8 4 9
ENROLL AS "RF"
LOOP 1
(SOUND)
5 8 0 2 M N 2
ENROLL AS
"UR" OR "RF"
LOOP
1
5 8 5 0 ( G B D )
ENROLL AS "RF"
(Green)
(Red)
(Yellow)
LOOP 1
5814
ENROLL AS "RF"
01000-012-V0
5 8 2 7 B D
PROGRAM
HOUSE ID
1
4
7
2
5
8
0
3
6
9
#
*
LOOP 1
(MOTION)
5 8 9 0 / 5 8 9 0 P I
ENROLL AS "RF"
LOOP
1
5 8 0 2 M N
ENROLL AS
"UR" OR "RF"
5 8 0 4 B D / 5 8 0 4 B DV
ENROLL AS "BR"
LOOP 4
YOU MUST
ENROLL
THIS BUTTON
SET
HOUSE
CODE
LOOP 3
LOOP 1
LOOP 2
•
•
••
•
•
••
•
•
•
• •
• •
•
•••
5804
ENROLL AS "BR"
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
OF
F
LOOP 3
ON
5 8 1 6 T E M P
ENROLL AS "RF"
LOOP 1
(TERMINALS)
5 8 1 7
ENROLL AS "RF"
LOOP 2
(AUX.
CENTER)
LOOP 1
(PRIMARY)
LOOP 3
(AUX.
RIGHT)
5 8 1 6
ENROLL AS "RF"
LOOP 1
(TERMINALS)
LOOP 2
(REED)
5 8 1 6 M N
ENROLL AS "RF"
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
LOOP 2
(REED)
LOOP 3
(TERMINALS)
5 8 1 9 S ( W H S & B R S )
ENROLL AS "RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
LOOP 2
(REED)
5 8 1 9
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(TERMINALS)
5 8 2 7
SET
HOUSE ID
1
2
3
4
5
6
7
8
9
0
*
#
5 8 0 0 R L
5 8 0 1
ENROLL AS
"UR" OR "RF"
LOOP 3
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
UL
The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5814, 5816TEMP, 5819, 5819S(WHS & BRS), 5827BD, and
5850(GBD) transmitters are not intended for any UL installations.
-5-