ADEMCO LYNXR Quick Start Manual Download Page 5

Step

Action

4.

Set RF House ID in the wireless keypads as follows:

a.

5827 wireless keypad - Set the keypad’s DIP switches to the RF House ID programmed in field *24.

b.

5804BD button key or 5827BD keypad - Set the RF House ID per its instructions.

c.

Powerline Carrier Devices - Set their House ID to “A,” (programmed as “0”) or use field *25 to change the ID to avoid
conflicts with existing installations.

5.

Set the Real-Time Clock as follows:

a.

Enter time/date setting mode by entering the User Code + FU [63].

b.

The hour prompt is displayed. Enter the correct hour, then press [*] to accept and advance.

c.

For each subsequent prompt, enter the correct value, then press [*].

d.

The system will exit this mode automatically after entering the year, or if no keys are pressed for 1 minute.

6.

Test the system as follows:

a.

After installation and programming, enter Installer Code + TEST.

b.

To exit Test mode, enter Installer Code + OFF.

7.

Assign desired User Codes by following the procedures on the next page and in the User Guide. Show the user how to perform
the various system functions.

8.

Perform site-initiated downloader session (to load central station ID) by Installer Code + [#] + [1].

5800 Series Transmitter Loop Numbers: The following illustration shows the compatible transmitters and their associated
input types and loop designations.

LOOP 1

5806/5807/5808/5808LST

ENROLL AS "RF"

LOOP 1

5809

ENROLL AS "RF"

5 8 1 8

ENROLL AS "RF"

LOOP 1

5 8 4 9

ENROLL AS "RF"

LOOP 1
(SOUND)

5 8 0 2   M N 2

ENROLL AS

"UR" OR "RF"

LOOP

1

5 8 5 0   ( G B D )

ENROLL AS "RF"

(Green)

(Red)

(Yellow)

LOOP 1

5814

ENROLL AS "RF"

01000-012-V0

5 8 2 7 B D

PROGRAM

HOUSE ID

1

4

7

2

5

8

0

3

6

9

#

*

LOOP 1
(MOTION)

5 8 9 0 / 5 8 9 0 P I

ENROLL AS "RF"

LOOP

1

5 8 0 2   M N

ENROLL AS

"UR" OR "RF"

5 8 0 4 B D / 5 8 0 4 B DV

ENROLL AS "BR"

LOOP 4
YOU MUST
ENROLL
THIS BUTTON

SET

HOUSE

CODE

LOOP 3

LOOP 1

LOOP 2

••

••

• •

• •

•••

5804

ENROLL AS "BR"

LOOP 1

LOOP 2

LOOP 4

YOU MUST

ENROLL

THIS

BUTTON

OF

F

LOOP 3

ON

5 8 1 6 T E M P

ENROLL AS "RF"

LOOP 1
(TERMINALS)

5 8 1 7

ENROLL AS "RF"

LOOP 2
(AUX.
CENTER)

LOOP 1
(PRIMARY)

LOOP 3
(AUX.
RIGHT)

5 8 1 6

ENROLL AS "RF"

LOOP 1
(TERMINALS)

LOOP 2
(REED)

5 8 1 6 M N

ENROLL AS "RF"

LOOP 1
(TERMINALS)

ALTERNATE

POSITION

FOR LOOP 2

LOOP 2
(REED)

LOOP 3

(TERMINALS)

5 8 1 9 S   ( W H S   &   B R S )

ENROLL AS "RF"

LOOP 1
(INTERNAL
SHOCK
SENSOR

LOOP 2

(REED)

5 8 1 9

ENROLL AS "RF"

LOOP 2

(REED)

LOOP 3

(TERMINALS)

LOOP 1
(TERMINALS)

5 8 2 7

SET

HOUSE ID

1

2

3

4

5

6

7

8

9

0

*

#

5 8 0 0 R L

5 8 0 1

ENROLL AS

"UR" OR "RF"

LOOP 3

LOOP 1

LOOP 2

LOOP 4

YOU MUST

ENROLL

THIS

BUTTON

UL

The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5814, 5816TEMP, 5819, 5819S(WHS & BRS), 5827BD, and
5850(GBD) transmitters are not intended for any UL installations.

-5-

Reviews: