SPECIFICATIONS
Picture Elements
ACM574TP 768 (H) x 494 (V)
ACM574TPX and ACM575X 752 (H) x 582 (V)
ACC484TP 768 (H) x 494 (V)
ACC484TPX and ACC485TPX 752 (H) x 582 (V)
Synchronization System
AC line lock or internal oscillator
Horizontal Resolution
ACM574... and ACM575X 570 TV Lines
ACC484... and ACC485TPX 480 TV Lines
Minimum Illumination
ACM574... and ACM575X 0.1 lux at f1.2
ACC484... and ACC485TPX 0.7 lux at f1.2
Signal-to-Noise Ratio
monochrome
50 dB (AGC off); color 48 dB (AGC off)
Gain Control
Automatic
Vertical Phase
Adjustable 0° ±120°
Automatic Gain Control
Selectable on or off
Backlight Compensation
8 user-selectable windows
Scanning System
NTSC: 525 lines, 2:1 interlace; PAL: 625 lines, 2:1 interlace
Signal Processing
Digital Signal Processing
Auto Iris Lens Type
Selectable for Direct Drive or Video Drive
Video Output
1 Vp-p, 75 ohms
Iris Control Range
NTSC: 1/60 - 1/100,000 second; PAL: 1/50 - 1/100,000 second
Power Requirements
low voltage types 20-29 VAC or 11-28 VDC
mains voltage types 98 - 260 VAC 50/60Hz
Power Consumption
Less than 5 watts
Lens Mount
C/CS mount with adjustable back focus
Camera Mount
2 x 1/4-20 threaded mounting point
Operating Temperature
Low voltage types -10° to 60°C (14° to 140°F)
Mains powered types -10° to 50°C (14° to 122°F)
Storage Temperature
-10° to 70°C (14° to 158°F)
Safety
CE EN60950
UL UL2044
Humidity
Operating: 20 - 80% RH (non-condensing)
Storage: 20 - 90% RH (non-condensing)
Weight (without lens)
Low voltage types 0.3 kg (0.66lb)
Mains powered types 0.4 kg (0.88 lb)