INSTALLING DIRECT (OR D.C.) DRIVE LENSES

1. Turn the back focus adjustment ring fully clockwise (when viewed from the front)—see

Back Focus Adjustment

.

2. Fit the lens to the camera and connect it according to the diagram below.

 

The maximum load for this type of lens must not exceed 25mA

3. Set the Auto Iris lens selector (switch 5, figure 1) to DD.
4. Turn the Electronic Iris (EI) and Automatic Gain Control (AGC) features OFF.
5. If the lens has a focussing ring fitted, set it to infinity (

¥

) and then adjust the back focus—

see 

Back Focus Adjustment

.

6. With typical scene illumination, set the DD Lens Level adjustment potentiometer (3, figure 1)

lens iris for the correct exposure. This can be achieved either visually, or by using an

oscilloscope to set the output of the camera to 1V peak-peak.

7. If the scene lighting conditions are extremely uneven, it may be necessary to adjust the DD

Peak Average  potentiometer  (4,  figure  1)—see 

DD  Peak  Average Adjustment

Potentiometer 

.

8. Ensure the Automatic Gain Control (AGC) features is turned ON.

INSTALLING VIDEO DRIVE LENSES

1. Turn the back focus adjustment ring fully clockwise (when viewed from the front)—see

Back Focus Adjustment

.

2. Fit the lens to the camera and connect it according to the diagram below.

 

The maximum load for this type of lens must not exceed 50mA

3. Set the Auto Iris lens selector (switch 5, figure 1) to AI.
4. Turn the Electronic Iris (EI) and Automatic Gain Control (AGC) features OFF.
5. If the lens has a focussing ring fitted, set it to infinity (

¥

) and then adjust the back focus—

see 

Back Focus Adjustment

.

Damp (-)

Damp (+)

Drive (+)

Drive (-)

DD Lenses

AI Lenses

Lens supply (+)

Video Drive signal

Lens Ground

Summary of Contents for ACC484TP

Page 1: ...DSP Series CCD Cameras Installation Instructions Read these instructions first ACM574TP ACM574TPX ACM575X ACC484TP ACC484TPX ACC485TPX...

Page 2: ...supply range Cameras must only be used in clean dry dust free environments unless housed in suitable protective housings to IP65 or better ELECTROMAGNETIC COMPATIBILITY EMC This is a class B product...

Page 3: ...eter 8 DD Lens Level Adjustment Potentiometer 8 DD Peak Average Adjustment Potentiometer 8 Auto iris lens Type Selector Switch Video Drive or Direct DC Drive 8 Auto iris lens Connector 9 Separated Y C...

Page 4: ...or blue removeable connector fitted to the back of the camera Option Mono Color Resolution TVL Sensitivity lux f1 2 CCD Sensor size Scanning system PAL Scanning system NTSC Digital Signal Processing D...

Page 5: ...sfer on off F Sharpness on off G Gamma selection H AGC on off J Electronic Iris on off K Backlight Compensation on off L Synchronisation select M Power LED on off 1 Peak White Inversion adjustment 2 L...

Page 6: ...the lens itself for a video drive type lens must be set to peak BACKLIGHT COMPENSATION The backlight compensation feature can be used to eliminate the effect of an area of strong background lighting...

Page 7: ...rker areas of a scene or 1 0 for a more linear response The default setting is 0 45 AUTOMATIC GAIN CONTROL AGC ON OFF The Automatic Gain Control feature can improve picture quality when the level of s...

Page 8: ...the lens iris opening is increased If the DC voltage is greater than the reference level the lens iris opening is decreased This control loop attempts to continually match the DC voltage derived from...

Page 9: ...witch TWISTED PAIR VIDEO OUTPUT TERMINALS SUFFIX TP CAMERAS ONLY These terminals provide a composite video output signal which may be transmitted over a twisted pair connection to equipment furnished...

Page 10: ...SMUSTBECONNECTEDTOAPROTECTIVEEARTHGROUND Ensure that a secure means of isolation from the mains is provided for the camera in accordance with the national wiring regulations of the country of installa...

Page 11: ...adjustment ring fully clockwise when viewed from the front see Back Focus Adjustment 2 Fit the lens to the camera 3 If the lens has a focussing ring fitted set it to infinity and then adjust the back...

Page 12: ...y or by using an oscilloscope to set the output of the camera to 1V peak peak 7 If the scene lighting conditions are extremely uneven it may be necessary to adjust the DD Peak Average potentiometer 4...

Page 13: ...c Gain Control AGC features is turned ON CAMERA MOUNTING Mounting points are provided on the top and bottom of the camera and are used to mount the camera on a bracket or tripod They are designed to a...

Page 14: ...Iris Check Auto iris lens selector switch dipswitch 5 figure 1 is set to AI Increase level on lens Check wiring connections Try lens on another camera or known good lens on camera Dark picture Check...

Page 15: ...System NTSC 525 lines 2 1 interlace PAL 625 lines 2 1 interlace Signal Processing Digital Signal Processing Auto Iris Lens Type Selectable for Direct Drive or Video Drive Video Output 1 Vp p 75 ohms...

Page 16: ...lding 388 Castle Peak Road Tsuen Wan New Territories Hong Kong www ademco com hk Tel 852 2405 2323 ADEMCO France Parc Gutenberg 13 Voie La Cardon P 0 91120 Palaiseau France www securityhouse nl Tel 33...

Reviews: