background image

 

K3897V1  8/02 

6128RF 

Keypad/Transceiver 

INSTALLATION INSTRUCTIONS 

About the 6128RF 

The 6128RF is a combination unit that contains: 

• 

A 6128 Fixed Addressable Keypad 

• 

A 5881M RF Receiver 

• 

A 5800TM Transmitter Module 

• 

A normally-open relay output.   

The 6128RF Keypad/Transceiver may be used on any control panel that supports the 6128 Keypad. 

Features of the 6128RF 

Wireless Features 

• 

Supports up to 8 wireless keys locally (programmed directly into 6128RF) without occupying any zones of 
the control panel. 

• 

Supports button-type transmitters (5804, 5804BD) for local operation. 

• 

Supports a maximum of 16 transmitters programmed into any 5800 Series supported control panel. 

• 

Provides low battery indications for the local wireless keys. 

• 

Supports wireless keys with encryption (high security) (e.g., 5804E). 

• 

Provides a nominal range of 200' for the RF transmitters (some transmitters have a shorter range). 

• 

Supports RF Jam detection when the receiver is enabled. 

• 

Provides wireless key support for control panels that do not support RF (such as 4110DL). 

 

UL

 

The following transmitters are not intended for use in UL installations: 
5804, 5804BD, 5804BDV, 5804WATCH, 5804E and 5827BD. 

 

Programming Features 

• 

Provides an "Auto Enroll" mode for programming of the wireless keys. 

• 

Provides a method for deleting a serial number and re-enrolling a new one in its place. 

• 

Provides default settings for the functions of the wireless keys. 

Additional Features 

• 

Can send status signals (Armed, Ready, etc.), to bi-directional units such as 5804BD and 5827BD. 

• 

Can operate the on-board relay in conjunction with the receiver (trip a garage door opener). 

• 

Can activate relays programmed into the control panel. 

• 

Provides an "End User" mode to enable/disable local wireless keys (i.e., if a user accidentally loses a 
wireless key). See the 6128RF User Guide for this procedure. 

Application Guidelines for the 6128RF 

Use the following guidelines when planning an installation: 

• 

Local wireless keys are programmed directly into the 6128RF and may be used regardless of whether the 
RF receiver is enabled or disabled. 

• 

If using bi-directional devices, be sure to enable the transmitter module in the 6128RF. 

• 

If transmitters are programmed into the control panel, be sure to enable the receiver. (Make sure you do not 
exceed the number of receivers supported by the control panel). 

• 

If a local wireless key is programmed to arm/disarm or to trigger a relay on the control panel, a user code 
must be entered into the 6128RF. This user code must also be programmed into the control panel. 

• 

You must set the House ID only if you are using RF keypads and/or Bi-directional devices 

AND

 the House 

ID Source is the 6128RF (Local). 

 

Summary of Contents for 6128RF

Page 1: ...the wireless keys Provides a method for deleting a serial number and re enrolling a new one in its place Provides default settings for the functions of the wireless keys Additional Features Can send s...

Page 2: ...If set for Local on a partition control the 6128RF s partition assignment must match the one programmed in the BD device Installing the 6128RF Locate the 6128RF in an area and at a height where it is...

Page 3: ...s the information then moves you to the next prompt The keypad will beep twice The key erases the current information and moves you back so you may enter the correct information Enter a Program Addres...

Page 4: ...structions for the acceptable keypad and receiver addresses If you are using a wireless key in high security mode 5804E in the control panel it will occupy one of the devices in the 6128RF Programming...

Page 5: ...he House ID is needed only if an RF keypad and or bi directional units is used and House ID source is set for Local The House ID entered here MUST match the House ID programmed in the RF keypad and th...

Page 6: ...relay for 2 seconds LOOP 2 Disarm ON OFF 5804 002 V0 5804 LOOP 3 Arm AWAY LOOP 4 Arm STAY LOOP 1 Close on board relay for 2 seconds LOOP 2 Disarm 5804BD 002 V0 5804BD SET HOUSE CODE 7 Repeat step 6 fo...

Page 7: ...ing of the Program Mode the 6128RF will alternately flash Ad the 2 digit keypad address and the 2 digit receiver address If the either of these is incorrect repeat steps 1 through 3 under Programming...

Page 8: ...er 165 Eileen Way Syosset New York 11791 warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and...

Reviews: