CANADIAN DEPARTMENT OF COMMUNICATIONS

(DOC) STATEMENT

NOTICE

The Canadian Department of Communications label identifies certified equipment. This certification means that the
equipment meets certain telecommunications network protective, operational and safety requirements. The Department
does not guarantee the equipment will operate to the user's satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local
telecommunications company. The equipment must also be installed using an acceptable method of connection. In some
cases, the company's inside wiring as sociated with a single line individual service may be extended by means of certified
connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions
may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the
supplier. Any repairs or al terations made by the user to this equipment, or equipment malfunctions, may give the
telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines
and internal metallic water pipe system, if present, are connected together. This precaution may be particularly
important in rural areas.
Caution:   User should not attempt to make such connections themselves, but should contact the appropriate electric
inspection authority, or electrician, as appropriate.
The Load Number  (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a
telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any
combination of devices subject only to the require ment that the total of the Load Numbers of all the devices does not
exceed 100.

AVIS

L'étiquette du ministère des Communications du Canada identifie le matériel homologué.  Cette étiquette certifie que le
matériel est conforme à certaines normes de protection, d'exploitation et de sécurité des réseaux de télécommunications.
Le ministère n'assure toutefois pas que le matériel fonctionnera à la satisfaction de l'utilisateur.
Avant d'installer ce matériel, l'utilisateur doit s'assurer qu'il est permis de le raccorder aux installations de l'entreprise
locale de télécommuni cations. Le matériel doit également être installé en suivant une méthode acceptée de
raccordement. Dans certains cas, les fils intérieurs de l'en treprise utilisés pour un service individuel à la ligne unique
peuvent être prolongés au moyen d'un dispositif homologué de raccordement (cordon prolongateur téléphonique interne).
L'abonne ne doit pas oublier qu'il est possible que la conformité aux conditions énoncées ci-dessus n'em pèche pas la
dégradation du service dans certaines situations. Actuellement, les entreprises de télécommunications ne permettent pas
que l'on raccorde leur matériel aux prises d'abonnés, sauf dans les cas precis prévus par les tarifs particuliers de ces
entreprises.
Les réparations du matériel homologué doivent être effectuées pas un centre d'entretien canadien autorisé désigné par le
fournisseur. La compagnie de télécommunications peut demander à l'utilisateur de débrancher un appareil à la suite de
réparations ou de modifications effec tuées par l'utilisateur ou à cause de mauvais fonctionnement.
Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise en terre de la source d'énergie électrique,
des lignes téléphoniques de réseau de conduites d'eau, s'il y en a, soient raccordés ensemble. Cette précaution est
particulièrement importante dans les régions rurales.
Avertissement:   L'utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir recours à un service
d'inspection des in stallations électriques, ou à un électricien, selon le cas.
L'indice de charge  (IC) assigné à chaque dispositif terminal pour éviter toute surcharge indique le pourcentage de la
charge totale qui peut être raccordé à un circuit téléphonique bouclé utilisé par ce dispositif. La terminaison du circuit
bouclé peut être constituée de n'importe quelle combinaison de dispositifs, pourvu que la somme des indices de charge de
l'ensemble des dispositifs ne dépasse pas 100.

Summary of Contents for 4110XM

Page 1: ...S E C U R I T Y S Y S T E M 4110XM N5478V5 7 96 Installation Instructions Installation Instructions Installation Instructions SEE INSIDE COVER FOR IMPORTANT NEW FEATURES AND INFORMATION Previous Menu...

Page 2: ...dom time delay up to 1 hour If AC is restored before the report goes out no report will be sent 6 Telephone number entries can now contain and a 2 second pause Enter 11 for Enter 12 for Enter 13 for 2...

Page 3: ...10 The Mechanics of Programming 10 Entering Program Mode 10 Programming a Data Field 10 Reviewing a Data Field 10 Erasing an Entry in a Data Field 10 Downloading 10 Clearing All Data Fields 10 Exiting...

Page 4: ...osed Smoke could be blocked by the closed door Also an alarm in the hallway outside may not wake up the sleeper if the door is closed Install a smoke detector inside bedrooms where electrical applianc...

Page 5: ...a 12VDC 2 AMP output assumes a fully charged 4AH battery is connected Steady output for Burglary Panic or pulsing output for Fire Output is current limited Communication Formats Ademco Low Speed Stan...

Page 6: ...eet Optional Keyswitch 4116 Keyswitch ZONE RESPONSE TYPE CHARACTERISTICS Zone Response Type Characteristics 0 Zone Disabled 1 Entry Exit Burglary Provides exit delay time when panel is armed in any ar...

Page 7: ...CABINET DOOR BOTTOM RETAINER CLIP RETAINER CLIP NOTE POSITION RETAINER SLOTS LOCKED UNLOCKED Figure 1 Installing The Cabinet Lock Mount the PC board either alone or with the wireless receiver in the...

Page 8: ...right OFF this equals address 0 as shown in Figure 4 4 3 2 1 ON OFF MOUNTING HOLES INTERFERENCE INDICATOR LED CIRCUIT BOARD DIP SWITCH PLUG SOCKET INSERT IN RIGHT HAND TERMINALS ANTENNAS YELLOW RED B...

Page 9: ...Telephone Line IMPORTANT Make sure telephones on the premises are connected only through the alarm control panel disconnect from the incoming phone line at the telephone jack This is necessary to have...

Page 10: ...numbers into the system see program fields 24 and 76 thru 92 Do not permanently mount transmitters until transmission from each location has been verified see Section 5 TESTING THE SYSTEM for instruct...

Page 11: ...viewing a Data Field Press plus Field No Note the following Data will be displayed for that field number entry by entry a beep will be heard between entries and three beeps after the last No changes w...

Page 12: ...TRY DELAY PERIMETER ARMED INTERIOR ARMED AWAY Security Code 2 Yes Yes Yes Yes STAY Security Code 3 Yes Yes Yes No INSTANT Security Code 7 Yes No Yes No MAXIMUM Security Code 4 Yes No Yes Yes DISARM Se...

Page 13: ...hen all tests are finished and verify results with them Transmitter ID Sniffer Mode 1 Enter Master Code 3 The following will occur The keypad will display all zone numbers of wireless units programmed...

Page 14: ...played 4a Interrupted AC power supply 4b Wire run from transformer to control is too long 4a Check transformer connection and power line circuit breaker 4b Make sure wiring run is not longer than the...

Page 15: ...plies with Part 68 of the FCC rules On the front cover of this equipment is a label that contains among other information the FCC registration number and ringer equivalence number REN for this equipme...

Page 16: ...e tiquette certifie que le mat riel est conforme certaines normes de protection d exploitation et de s curit des r seaux de t l communications Le minist re n assure toutefois pas que le mat riel fonct...

Page 17: ...P 42 UP UP UP 43 UP UP 44 UP UP UP 45 UP UP 46 UP UP 47 UP 48 UP UP UP UP 49 U UP UP 50 UP UP UP 51 UP UP 52 UP UP UP 53 UP UP 54 UP UP 55 UP 56 UP UP UP 57 UP UP 58 UP UP 59 UP 60 UP UP 61 UP 62 UP 6...

Page 18: ...ors closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any material on the mirrors windows or any part of the optical system can reduce their det...

Page 19: ...UIT BOARD HANDSET BLACK RED 1000 OHMS EOLR 1000 OHMS EOLR ZONE 1 ZONE 2 HI LO HI LO 1000 OHMS EOLR 1000 OHMS EOLR ZONE 3 ZONE 4 HI LO HI LO MAXIMUM LOOP RESISTANCE EACH ZONE 300 OHMS PLUS EOLR RESPONS...

Page 20: ...YONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE...

Reviews: