ADEMCO 4110XM Installation Instructions Manual Download Page 11

                         - 11-

  Section 3.  PROGRAMMING THE SYSTEM

For actual program fields, a programming form is included at the center of this manual.

Entering Program Mode

Use one of the following methods:

Press both the [*] and [#] keys at the same time within 50 seconds after power is applied to the Control.
or

After power-up, enter the [Master Code] + 8 + 0 (default Master Code is 4110)

This method is disabled if you exit the program mode using *98 instead of *99.  See "Exiting Program
Mode" later in this section.

Following entry into program mode, data field *20 will be displayed (this is the first field in the system).
The system will now accept entries for field *20.

Programming a Data Field

↓ 

Field Number

20

Press [*] plus [Field No.] (e.g., *20), and then make the required entry.  Note the following:

The keypad beeps three times when the data field has been completely programmed

The next Field No. is displayed.  If you do not want to program this field, press  [*] + the Field No. you
want to program.

If the number of digits that you need to enter in a data field is less than the maximum digits available
(e.g., the phone number field), enter the desired data, then press [*] + the next Field No. to be
programmed.

If you try to enter a non-existent field, the keypad will display EE or Entry Error.  Simply re-enter [*]
plus a valid Field No.

Reviewing a Data Field

Press [#] plus [Field No. ].  Note the following:

Data will be displayed for that field number, entry by entry (a beep will be heard between entries and
three beeps after the last).

No changes will be accepted in this mode.

If you try to enter a non-existent field, the keypad will display EE or Entry Error.  Simply re-enter [#]
plus a valid field number.

Erasing an Entry in a Data Field

Applies only to fields *40-*43, and *94.
Press [*] plus Field No. plus [*].

Downloading

*96  resets the Subscriber Account number and CSID in preparation for an initial download.  If *97 was

entered previously, *96 must  be entered last.  The control can either be initiated from the control panel
(site) by entering [Master Code] + # + 1, or from the downloading computer (station).

A new Telco hand-off feature allows a technician or user at the site to call the downloading facility from the
control panel phone line and initiate a site download. By entering the Master Code + [#] + [1] while on the
line, the control will immediately be on-line with the modem at the downloading facility, where the operator
can begin downloading.

Clearing All Data Fields

*97 clears (zeros) all data fields.  The Master Code will now be 0 0 0 0.

WARNING

DO NOT PRESS *97 IF ANY PROGRAMMING HAS BEEN DONE
PREVIOUSLY; DATA ALREADY PROGRAMMED INTO THE SYSTEM WILL
BE DELETED.

Exiting the Programming Mode

*98 inhibits re-entry into the programming mode with the use of the Master Code.

*99  allows re-entry into the program mode using Master Code + 8 + 0.

Summary of Contents for 4110XM

Page 1: ...S E C U R I T Y S Y S T E M 4110XM N5478V5 7 96 Installation Instructions Installation Instructions Installation Instructions SEE INSIDE COVER FOR IMPORTANT NEW FEATURES AND INFORMATION Previous Menu...

Page 2: ...dom time delay up to 1 hour If AC is restored before the report goes out no report will be sent 6 Telephone number entries can now contain and a 2 second pause Enter 11 for Enter 12 for Enter 13 for 2...

Page 3: ...10 The Mechanics of Programming 10 Entering Program Mode 10 Programming a Data Field 10 Reviewing a Data Field 10 Erasing an Entry in a Data Field 10 Downloading 10 Clearing All Data Fields 10 Exiting...

Page 4: ...osed Smoke could be blocked by the closed door Also an alarm in the hallway outside may not wake up the sleeper if the door is closed Install a smoke detector inside bedrooms where electrical applianc...

Page 5: ...a 12VDC 2 AMP output assumes a fully charged 4AH battery is connected Steady output for Burglary Panic or pulsing output for Fire Output is current limited Communication Formats Ademco Low Speed Stan...

Page 6: ...eet Optional Keyswitch 4116 Keyswitch ZONE RESPONSE TYPE CHARACTERISTICS Zone Response Type Characteristics 0 Zone Disabled 1 Entry Exit Burglary Provides exit delay time when panel is armed in any ar...

Page 7: ...CABINET DOOR BOTTOM RETAINER CLIP RETAINER CLIP NOTE POSITION RETAINER SLOTS LOCKED UNLOCKED Figure 1 Installing The Cabinet Lock Mount the PC board either alone or with the wireless receiver in the...

Page 8: ...right OFF this equals address 0 as shown in Figure 4 4 3 2 1 ON OFF MOUNTING HOLES INTERFERENCE INDICATOR LED CIRCUIT BOARD DIP SWITCH PLUG SOCKET INSERT IN RIGHT HAND TERMINALS ANTENNAS YELLOW RED B...

Page 9: ...Telephone Line IMPORTANT Make sure telephones on the premises are connected only through the alarm control panel disconnect from the incoming phone line at the telephone jack This is necessary to have...

Page 10: ...numbers into the system see program fields 24 and 76 thru 92 Do not permanently mount transmitters until transmission from each location has been verified see Section 5 TESTING THE SYSTEM for instruct...

Page 11: ...viewing a Data Field Press plus Field No Note the following Data will be displayed for that field number entry by entry a beep will be heard between entries and three beeps after the last No changes w...

Page 12: ...TRY DELAY PERIMETER ARMED INTERIOR ARMED AWAY Security Code 2 Yes Yes Yes Yes STAY Security Code 3 Yes Yes Yes No INSTANT Security Code 7 Yes No Yes No MAXIMUM Security Code 4 Yes No Yes Yes DISARM Se...

Page 13: ...hen all tests are finished and verify results with them Transmitter ID Sniffer Mode 1 Enter Master Code 3 The following will occur The keypad will display all zone numbers of wireless units programmed...

Page 14: ...played 4a Interrupted AC power supply 4b Wire run from transformer to control is too long 4a Check transformer connection and power line circuit breaker 4b Make sure wiring run is not longer than the...

Page 15: ...plies with Part 68 of the FCC rules On the front cover of this equipment is a label that contains among other information the FCC registration number and ringer equivalence number REN for this equipme...

Page 16: ...e tiquette certifie que le mat riel est conforme certaines normes de protection d exploitation et de s curit des r seaux de t l communications Le minist re n assure toutefois pas que le mat riel fonct...

Page 17: ...P 42 UP UP UP 43 UP UP 44 UP UP UP 45 UP UP 46 UP UP 47 UP 48 UP UP UP UP 49 U UP UP 50 UP UP UP 51 UP UP 52 UP UP UP 53 UP UP 54 UP UP 55 UP 56 UP UP UP 57 UP UP 58 UP UP 59 UP 60 UP UP 61 UP 62 UP 6...

Page 18: ...ors closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any material on the mirrors windows or any part of the optical system can reduce their det...

Page 19: ...UIT BOARD HANDSET BLACK RED 1000 OHMS EOLR 1000 OHMS EOLR ZONE 1 ZONE 2 HI LO HI LO 1000 OHMS EOLR 1000 OHMS EOLR ZONE 3 ZONE 4 HI LO HI LO MAXIMUM LOOP RESISTANCE EACH ZONE 300 OHMS PLUS EOLR RESPONS...

Page 20: ...YONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE...

Reviews: