background image

Notice

1. Keep your fingers clean when using this product.

2. In the state of new lock (factory setting), the lock can be unlocked with any fingerprint.

3. When opening the door, if the lock beeps an alarm and the indicator light flashes red, it's

    indicating the lock is in insufficient voltage level. Please change the batteries.

4. This product can save 99 fingerprints, among which 3 are master fingerprints (Code: 00-02), 

    and other 96 are member fingerprints (Code: 03-98). Additionally there is also a set of spare 

    password for unlocking (Code: 99).

5. Deletion of fingerprint is to delete each fingerprint separately according to its code; the

    fingerprint cannot be deleted unless you know the code.

6. The dirt on the surface of fingerprint collection window may affect the normal use. Therefore

    please keep it clean.

7. Do not clean the lock surface with corrosive substance, or else the protection layer may be 

    damaged and thus influence the gloss of the lock surface. Therefore please clean the lock

    surface periodically with 

furniture polish wax

 (e.g. 

Pledge

).  

8. If the latch bolt fails to draw back and forth freely, or the door cannot be closed normally due 

    to the distortion of the door, please adjust the strike plate's position.

9. When the fingerprint and password fails to work, use the mechanical key to open the door; 

    please keep the mechanical key in a proper place.

Trinity 788 Operation Manual

Trinity 788 Operation Manual

Right method to apply fingerprint

Right

Notes:

When the red light on fingerprint collection window flashes, press your finger onto the

window, and then remove your finger after a beep; press your finger again after 2 seconds,

if you hear two long beeps, the collection is successfully completed.

Error in applying fingerprint

Wrong

Wrong

Wrong

Wrong

Wrong

Right

01

02

Summary of Contents for Trinity 788

Page 1: ...uture reference ADEL FINGERPRINT TECHNOLOGY LLC Add 20311 Valley Blvd Suite B Walnut CA 91789 USA Postal Code 91789 Toll Free 1 877 246 2335 E mail info adelfingerprint com ADEL GROUP ASIA LIMITED Add...

Page 2: ...eep it clean 7 Do not clean the lock surface with corrosive substance or else the protection layer may be damaged and thus influence the gloss of the lock surface Therefore please clean the lock surfa...

Page 3: ...back Button of battery cover Lock body back Lock surface back Back handle Contents I Assignment of fingerprint and password II Initialization of the door lock III Enrollment of master fingerprints me...

Page 4: ...door open state Door closed electric engine makes a rolling sound for the second time which indicates the lock is in door closed state 4 Enter passage mode the lock makes a beep and after the success...

Page 5: ...take user 01 as an example Operational procedure Indication of the lock In the state of new lock put any finger on the fingerprint collection window to enter the door open state Green light is on and...

Page 6: ...ingerprint window and enter door open state Green light is on and the LED displays the code of the master fingerprint Press Button to enter the enrollment mode A beep sound heard and the LED displays...

Page 7: ...master fingerprint Press Button to enter the enrollment mode A beep sound heard and the LED displays 0 Press Button or to choose the first digit 9 of the password code and press Button to confirm the...

Page 8: ...e Press Button to enter the deletion mode Green light is on and the LED displays the code of the master fingerprint The LED displays 0 Press Button or to choose the first digit 0 of the password code...

Page 9: ...e light on the fingerprint window flash one time with a relatively sharp and quick beep the LED displays 0 and stops display two seconds later Put the finger enrolled on the fingerprint window hold th...

Page 10: ...e to choose other five digits with the same method 2 In case the automatically start function fails press Button to start it manually 3 If the operation fails the red light will be on and two short be...

Page 11: ...en the door X Change of batteries Change of batteries completed Procdure Remove the battery cover Remove all the used batteries Load new batteries Notes 1 When loading the batteries operate correctly...

Page 12: ...f enrollment Red light is constantly on 1 Change the batteries 2 Check Cable connection 1 Low battery voltage 2 PCB failure Alarm sounds when open the door Low battery voltage Change the batteries No...