Notes:

1. The original password of the new lock (factory setting) is 

111111

, and this original

    password will be cleared at the time of the successfully enrollment of the master fingerprint

2. The spare password must be of 6 digits, which is an arbitrary combination of the figures 

0~9

;

3. Only one spare password can be set for each lock, and with the code 

99

. The spare

    password is the only password that can open the door, you can change it and delete it; 

    please refer to P.15 for deletion of password;

4. During the setting, the confirmed figure will be moved automatically to the tens place of the

    LED, with the figure to choose and confirm at the ones place;

Trinity 788 Operation Manual

Trinity 788 Operation Manual

V. Deletion of fingerprints (take user 03

 as an example)

Operational procedure

Indication of the lock

Put the master finger that has been enrolled 

on the fingerprint window and enter door open state

Press Button 

-

 to enter the deletion mode

Green light is on, 

and the LED displays the code of the master fingerprint

The LED displays 

0-

Press Button

+

 or 

-

 to choose the first

digit 

0

 of the password code, and press

Button

#

 to confirm the choice

The LED displays the figure 

0

 just set which jumps

to the tens place, and the ones place displays 

0

Continue to press Button 

+

 or 

-

 to adjust the seconddigit 

3

 of the

 fingerprint code,and press Button # to confirm

The LED displays the fingerprint code 

03

 and

flashes alternately.

Press Button 

#

 to reconfirm the fingerprint 

code to be deleted, and the deletion of

the member fingerprint is completed

The light on the fingerprint window flash one time

with a relatively sharp and quick beep, the LED

displays 

0-

 and stops display two seconds later

Notes:

1. Continue to input fingerprint code while the LED displays 

0-

, and repeat the operation for

    deletion of other fingerprint;

2. The fingerprint codes

00-02

are master fingerprints, while

03-98

are member fingerprints;

3. Th e deletion of the member fingerprint can only be completed when its fingerprint code  is available.

13

14

Summary of Contents for Trinity 788

Page 1: ...uture reference ADEL FINGERPRINT TECHNOLOGY LLC Add 20311 Valley Blvd Suite B Walnut CA 91789 USA Postal Code 91789 Toll Free 1 877 246 2335 E mail info adelfingerprint com ADEL GROUP ASIA LIMITED Add...

Page 2: ...eep it clean 7 Do not clean the lock surface with corrosive substance or else the protection layer may be damaged and thus influence the gloss of the lock surface Therefore please clean the lock surfa...

Page 3: ...back Button of battery cover Lock body back Lock surface back Back handle Contents I Assignment of fingerprint and password II Initialization of the door lock III Enrollment of master fingerprints me...

Page 4: ...door open state Door closed electric engine makes a rolling sound for the second time which indicates the lock is in door closed state 4 Enter passage mode the lock makes a beep and after the success...

Page 5: ...take user 01 as an example Operational procedure Indication of the lock In the state of new lock put any finger on the fingerprint collection window to enter the door open state Green light is on and...

Page 6: ...ingerprint window and enter door open state Green light is on and the LED displays the code of the master fingerprint Press Button to enter the enrollment mode A beep sound heard and the LED displays...

Page 7: ...master fingerprint Press Button to enter the enrollment mode A beep sound heard and the LED displays 0 Press Button or to choose the first digit 9 of the password code and press Button to confirm the...

Page 8: ...e Press Button to enter the deletion mode Green light is on and the LED displays the code of the master fingerprint The LED displays 0 Press Button or to choose the first digit 0 of the password code...

Page 9: ...e light on the fingerprint window flash one time with a relatively sharp and quick beep the LED displays 0 and stops display two seconds later Put the finger enrolled on the fingerprint window hold th...

Page 10: ...e to choose other five digits with the same method 2 In case the automatically start function fails press Button to start it manually 3 If the operation fails the red light will be on and two short be...

Page 11: ...en the door X Change of batteries Change of batteries completed Procdure Remove the battery cover Remove all the used batteries Load new batteries Notes 1 When loading the batteries operate correctly...

Page 12: ...f enrollment Red light is constantly on 1 Change the batteries 2 Check Cable connection 1 Low battery voltage 2 PCB failure Alarm sounds when open the door Low battery voltage Change the batteries No...

Reviews: