Function description: Transducer inputs
MSX-E3701-DIO
4
Function description: Transducer inputs
The Ethernet system
MSX-E3701-DIO
has 16 single-ended inputs for inductive displacement
transducers.
4.1
Pin assignment
To each M18 female connector, one displacement transducer can be connected. The differential
transducer supply consists of OSC+ and OSC-.
NOTICE!
With the Ethernet system MSX-E3701-DIO, only one type of
transducer can be connected to one system.
Exception: The option XT-370x-MIX enables the connection of up
to 16 different HB or LVDT transducer types per system. For this,
the frequency and the input resistance of the transducers must be
equal.
Table 4-1: Pin assignment: Transducer inputs
Half-bridge
LVDT
Pin No. Female connector,
5-pin, M18
Female connector,
5-pin, M18
1 OSC+
OSC+
2
GND
OSC-
3
Transducer signal
not connected
4
not connected
Transducer signal
5 OSC-
GND
OSC = oscillator voltage = supply voltage
www.addi-data.com 15