APPENDIX G - Using the optional ALIF4000 rack shelf
1
Install the empty ALIF4000 rack mount tray into your 19” rack frame and fully
secure it.
2
Place an ALIF4000 unit into each side of the rack mount tray so that their rear
panels butt up against the small pegs located on each of the side walls.
3
Locate the supplied thumbscrew and spacer.
4
Insert the thumbscrew through the spacer; then insert into the small hole at the
end of the center divider
(A)
.
5
Gently tighten the thumbscrew so that the spacer engages with the
inner edges of the two ALIF4000 units and holds them in place
(B)
.
6
Place the power adapters in the rear section of the
rack mount tray and connect them to their
respective ALIF4000 units.
7
Make all other necessary
connections to the
ALIF4000 units.
(A)
(B)
IMPORTANT: When mounting the ALIF units (and their
power adapters), ensure that the vents are not obscured
and that there is sufficient airflow. The operating
temperature range is 0 to 40ºC (0 to 104ºF) and must
not be exceeded. Each power adapter is rated at a
maximum of 68.24BTU/hr.
Note: Suitable for installation in
Information Technology Rooms in
accordance with Article 645 of the
National Electrical Code and NFPA 75.
An optional blanking plate (part number:
RMK12-BP) is available to seal the airflow
if only one ALIF4000 unit is installed within
a rack mount tray.