CHAPTER 3
Using terminal commands
23
FREQ
15535 FREQ 433925000 25000 0
#
RSSI
D
ESCRIPTION
Sets/returns the Relative Signal Strength Indicator threshold at
which the RF receiver must wake up.
P
ARAMETERS
The threshold value. For the A725, it can take values from 0 to
255; it is typically factory set to 42.
R
ETURNS
The instant RSSI value and the programmed threshold.
REMARKS
GET/SET
.
REMOTE
No.
E
XAMPLE
RSSI 50
15535 RSSI 0
#
RSSI
15535 RSSI 34 50 0
#
Note: The values of the RSSI threshold have no units, they are arbi-
trary. However, a value of
160
corresponds approximately to
the maximum value allowed in the addVANTAGE software
(that is, 8 µV).
ID
D
ESCRIPTION
Sets/returns the node’s ID.
P
ARAMETERS
The node ID.
R
ETURNS
The node ID.
REMARKS
GET/SET
.
REMOTE
Yes,
SET
only.
E
XAMPLE
ID 4557
15535 ID 0
#