background image

5

 

 

Introduction 

Meet the Ultra Alarm Control System 

Thank you for choosing to protect your premises with a 

Ultra-8/16

 of Australian Security

Supplies & ADC.

Ultra Alarm panel of Australian Security Supplies is a highly advanced, multifunction 
Wireless alarm control system, designed to flawlessly manage your security system at 
home or at business, protects you against burglary and supports the operation of 
electronic devices. 

The Ultra-8/16 has many incredible program options that can enhance the standard features 
of the panel from simple “Home Automation” to “Radio control” and Voice Prompted 
Command control”. Please ask your installer to find out more about these powerful 
features. 

You can phone your home to check or change the status of any output using the keys on 
your phone. Arm or disarm the whole house or just one area, all with  voice confirming 
your selections.  

Imagine turning on the spa before leaving work so it is hot when you get in the door. The 
under-floor heating has just automatically switched on using the on board timer and you 
have just opened the rollerdoor and disarmed the garage from your cell phone so the 
white ware repairman can work on your washer. 

It also has a comprehensive alarm event memory that stores all of the controller activity 
with the time and date. 

 

Typical Alarm System Configuration 

The protected premises can be divided up to 8 or 16 zones, as defined by the installation 
scheme.  The protected area can be grouped into 4 separate partitions (A,B,C,D).  The 
system can be grouped for User ‘s convenience to separate, in a business environment, 
the offices from the warehouse area, or in a private residence, the different rooms of the 
home, e.g., living room, bedroom, etc.  

Each zone can react differently to various events, to generate an alarm or activate a 
device. 

The system can be armed in two different modes: 
1) Arm –the protected areas are entirely vacated 
2) Stay –people and pets populate the protected areas. 

The User who has access to the keypad's control features, can change the settings. 

The system can be accessed via multiple keypads (each located at a different site).  Up 
to 8 keypads can be integrated into the system. Access levels and Users’ access codes 
are detailed below.  

 

 

Summary of Contents for Ultra-8/16

Page 1: ...Ultra 8 16 LCD Keypad Operators Guide TO SUIT PANEL VERSION 8 65 6 20 Advanced Digital Controls ASLCD IM V2 0...

Page 2: ...t the Ultra 8 16 Control Panels Firmware Versions 8 65 6 20 To the best of our knowledge the information contained in this manual is correct at the time of printing Advanced Digital Controls NZ Ltd re...

Page 3: ...the System before Exit 11 How to Arm the System when Staying Home 12 How to Arm Partitions 13 How to Bypass Zones 14 How to use Chime If enable by Installer 14 Emergency Alerts 15 Generate Threat or D...

Page 4: ...User Code 19 How to Add or Change Telephone Numbers 19 How to set Time and Date 20 How to start Walk test Mode 20 Customizing your Keypad 21 How to Adjust Keypad Backlight Level 22 How to Adjust Buzz...

Page 5: ...tched on using the on board timer and you have just opened the rollerdoor and disarmed the garage from your cell phone so the white ware repairman can work on your washer It also has a comprehensive a...

Page 6: ...ns are used for the following functions Numeric Keys In Operating mode the numeric keys are used for entering Access codes In Program mode the numeric keys are used for entering program addresses and...

Page 7: ...in Table 2 Table List of LED Indicators Design Function Bypass Indicates that there are bypassed zones Stay Indicates that the system is armed in STAY mode Armed Indicates that the system is fully arm...

Page 8: ...tes full arm Full Arm C ARM Initiates full arm Only if enabled by installer Disarm during exit C ARM Disarms the system during exit delay Only when slow beeping is emitted Disarm C C O D E C ENTER Dis...

Page 9: ...play of events from memory ENTER cancels memory readout Displays events and automatically scrolls to the next event every 2 5 sec Use arrow key to scroll up manually Chime Enable dis able C CHIME Enab...

Page 10: ...LED backlight level CCONTROL Hold CONTROL and press repeatedly to decrease light Increase Speaker volume CCONTROL 6 Hold CONTROL and press 6 repeatedly to Increase volume Decrease Speaker volume CCON...

Page 11: ...system type date and time and the green Ready indicator is lit Before leaving premises the system has to be armed Arming the alarm system will turn on all detectors in the partition s being armed Whe...

Page 12: ...ones Consequently interior movements will be ignored by the system When the system is Ready press STAY and the system prompts you to enter user code and then ENTER Quick Stay When enabled by the insta...

Page 13: ...xit During exit delay you can leave premises At the end of the procedure the ARMED indicator lights up to indicate that the system is armed and the system message is displayed The indicators may go ou...

Page 14: ...s more than one zone press BYPASS Bypass indicator lights up to indicate that the system is in bypass mode Add the zone number e g 03 one or more zones following press ENTER the Bypass indicator light...

Page 15: ...r The duress digit shifts up your usual code by one digit If your code is 345 and 8 is your duress digit than entering 8345 will modify your code The modified duress code will disarm the system in a n...

Page 16: ...ts that may occur are indicated by trouble messages and the Trouble indicator is lit Press MEMORY to read out messages and other events stored in memory Any failure or abnormal events that may occur a...

Page 17: ...r control mode the system prompts you to enter device and then ENTER to activate or deactivate the selected device How Local command control works If a command control code for outputs is programmed a...

Page 18: ...hts the holder of the Master code can ask the installer to define several User profiles Access rights are listed below User code has Area A and or B or C or D permission User code can arm and or disar...

Page 19: ...ser Code While in CLIENT mode press PROG and the User number 2 to 99 you intend to delete The display shows the code Press CONTROL and 0 simultaneously to delete User code Press ENTER to save the chan...

Page 20: ...NTER 1 31 ENTER Ultra 16 location 825 Where 1 31 the current date 4 Press PROGRAM 406 ENTER 1 12 ENTER Ultra 16 location 826 Where 1 12 the current month 5 Press PROGRAM 407 ENTER YY ENTER Ultra 16 lo...

Page 21: ...er this mode press simultaneously CONTROL and ARM for 2 seconds The display will show Local Mode kb From hereon you can change the numeric description of a zone to a textual description Press PROG 1 t...

Page 22: ...Program Area Description In client mode Press PROG 998 and then ENTER You may edit any character one per each area To save changes press ENTER To update and transfer programmed textual information fro...

Page 23: ...answers the call the first thing you will hear over the phone is a burst of modem tone for two seconds After this tone has stopped you must enter the access code which is associated with the Command m...

Page 24: ...sage or the appropriate tone and then the status can be changed with the button on the remote telephone Note For output control you must enter in the 4 digit code e g 4321 followed by the output numbe...

Page 25: ...any other basis of liability whatsoever even if the loss or damage is caused by Crow s own negligence or fault Crow does not represent that this product can not be compromised or circumvented that thi...

Page 26: ...r changes and customizations User Name Out Device Designation Zone Zone Name 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 18 19 20 21 22 23 24 25 26...

Page 27: ...27 Notes...

Reviews: