Faults, Warnings, and Status Messages
Table 4-3
9-pin D-sub Pin Connector Functions
This interface can monitor three single external alarm contacts (Alarm Sense Input 1
This interface monitors the output contact closures from a Universal Power Supply
(UPS). Verify the output contact closure state (normally closed or normally open) of
the UPS, and set the appropriate contact definition using AdminBrowser.
• Faults are service impacting.
• Warnings indicate a possible service impact.
• Status messages are generally not service impacting.through 3).
4.4
Faults, Warnings, and Status Messages
Both fault and warning conditions of the Expansion Hub and attached RAUs are
reported to the Main Hub. Only faults are indicated by LEDs.
For more information, refer to Appendix C, “Faults, Warnings, Status Tables,” on
page C-1.
NOTE:
You can select what type of events AdminBrowser displays. Refer
to Section 3.5.2 View Preference 3-12.
Pin
Function
1
Alarm Sense Input (DC Ground)
2
Alarm Sense Input 3
3
Alarm Sense Input 2
4
N/C
5
N/C
6
DC Ground (common)
7
N/C
8
Alarm Sense Input 1
9
N/C