24
American Dryer Corp.
112144 - 46
Check your national and local code for breaker and wire size
7/9/14
NOTE:
Contact factory for electrical information not listed.
NOTE: ADC
reserves the right to make changes in specifications at any time without notice or
obligation.
ADE-320 / ADE-330
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
NOTES:
A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact
voltage.
When fuses are used they must be dual element, time delay, current limiting, class
RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either
local and/or National Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others,
calculate/verify correct breaker size according to appliance amp draw rating and
type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
kW
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
208
1ø
2
15
77
—
100
220
1ø
2
13
65
—
90
240
1ø
2
15
67
67
90
208
3ø
3
15
47
—
60
220
3ø
3
13
40
38
50
240
3ø
3
15
42
40
60
480
3ø
3
15
41
—
60
230
3ø
3
14
—
39
50
380
3ø
4
13
—
24
40
416
3ø
4
15
—
25
40
Summary of Contents for AD-320
Page 20: ...16 American Dryer Corp 112144 46 ...
Page 21: ...112144 46 www adclaundry com 17 ...
Page 22: ...18 American Dryer Corp 112144 46 ...