Check your national and local codes for breaker and wire sizes
5/1/17
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the left side panel area behind top control (access) door. In the case of 208
VAC or 240 VAC, the supply voltage must match the electric service specifications of
the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
GAS AND STEAM
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT
:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY. For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
NON-REVERSING
120
1ø
2
8.7
—
15
208
1ø
2
5.2
—
15
220
1ø
2
4.8
3.8
15
230
1ø
2
4.8
4
15
240
1ø
2
—
5.6
15
208
3ø
3
3
—
15
230
3ø
3
3.2
3.8
15
240
3ø
3
3.2
3.6
15
380
3ø
3
2.9
—
15
380 / 400
3ø
4 or 3
—
2.2
15
416
3ø
4 or 3
—
2.2
15
460 / 480
3ø
3
2.1
—
15
REVERSING
230
3ø
3
—
6.7
15
380
3ø
3
8.2
—
15
416
3ø
4 or 3
—
3.5
15