ADC AD-120ES Installation Manual Download Page 27

113386-28

www.adclaundry.com

27

TIMING LEGEND

SPIN TIME

Adjustment Position Number

1

2

3

4

5

Time in Seconds*

30

60

90

120

150

DWELL (STOP) TIME

Adjustment Position Number

1

2

3

4

5

Time in Seconds*

5

6.3

7.6

8.9

10.2

* Values shown are +/- 1-second.

Reversing Timer Spin / Dwell Adjustments

Timer models have an electronic reversing timer in the
electrical service box, which is located in the upper left rear
area of the dryer.
Both the Dwell (stop) Time and the tumbler Spin Time are
adjustable by mode selection switches located on the
electronic timer (as noted in the illustration below).

Preoperational Instructions _________

Phase 7 Dryers

The L.E.D. display reads “READY” (no cycle in progress).
Press the letter on the keypad corresponding to the cycle
desired (i.e., key “D”).

NOTE:

 “0-40” will require the “START/ENTER” key to be

pressed after the number is selected in order to accept the
selection and start drying.

The dryer will then start.  (I.E., blower, tumbler, and heat.)
The L.E.D. display will read MANUAL DRYING CYCLE D,
00:00 MIN REMAIN.

NOTE: 

Press and hold the “UP ARROW” to view the tumbler

temperature at any time.
The dryer can be stopped at any time by pressing the “STOP/
CLEAR” key, at this time the dryer will go into a cycle pause.
If the “STOP/CLEAR” key is pressed again at this point, the
cycle that was in progress will be cancelled and returned to
the “READY” state.
Press and hold the “DOWN ARROW” to view the tumbler
RPM.

When the programmed drying time has expired, the Phase 7
non-coin microprocessor controller (computer) will proceed
into the Cool Down Cycle.
Once the Cool Down Cycle begins at the end of the heat
cycle, the L.E.D. display will read COOL DOWN TEMP ___/
___ MINUTES REMAINING.  At the end of the heat cycle,
the dryer will shut off the heat and continue the fan and
tumbler until the Cool Down Time or temperature is reached.

IMPORTANT:

 For more detailed information regarding the

microprocessor controller (computer) on the dryer, refer to
the microprocessor user’s manual included with the dryer.

Phase 5 Dryers

Turn on electric power to the dryer.
Make sure the main door is closed and the lint drawer is
securely in place.
Microprocessor controller (computer) system operational test
to start dryer...
L.E.D. display will read “FILL.”
Press the “E” (preprogrammed) cycle key on the keypad.
L.E.D. display will quickly read: “Ld30,” “Lc04,” and “F180”
(unless special programs requested).  These codes mean
that the dryer is in the timed mode and will operate with heat
of 180° F (82° C) for 30 minutes drying time and have a 4
minute cool down period.
Dryer will now start and the L.E.D. display will read “Dr30”
(dry mode for 30 minutes) and count down in minutes.

NOTE: 

The dryer can be stopped at any time by opening

main door or by pressing the “CLEAR/STOP” key.  To restart
the dryer, press the “ENTER/START” key or preprogrammed
cycle key (i.e., “E”).
Pressing keypad key “A,” “B,” “C,” “D,” or “F” will also start
the dryer.  The six preprogrammed drying cycles “A” through
“F” have been stored in the microprocessor controller’s
(computer’s) memory.  Refer to the computer programming
manual supplied with this dryer for these preprogrammed
cycles.

Dual Timer Dryers

Turn drying timer knob for a time of 20 minutes.
Select “High Temp.”
Push “Push to Start” button.
To stop dryer, open the main door.
Spin and dwell (stop) times are adjustable at the reversing
timer.

Summary of Contents for AD-120ES

Page 1: ...ez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Ne pas entre...

Page 2: ...___________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or...

Page 3: ...brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING Children should not be allowed to play on or near the dryer s Children should be supervised if near...

Page 4: ...perate dryer according to this manual and operator s manuals included with dryer may result in conditions which can cause serious injury death and or property damage Safety Precautions _______________...

Page 5: ...anufacturer s Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed from the...

Page 6: ...1 791 cfm 50 71 cmm EXHAUST CONNECTION DIAMETER 14 35 56 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A OVEN SIZE kW Btu hr kcal hr 72 245 700 61 900 75 6 258 000 65 000 VOLTAGE AVAILABLE...

Page 7: ...dclaundry com 7 AD 120ES Specifications __________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice...

Page 8: ...nufacturer reserves the right to make changes in specifications at any time without notice or obligation AD 120ES Specifications __________________________________________________________ WITH OPTIONA...

Page 9: ...OW 1 750 cfm 49 55 cmm HEAT INPUT 300 000 Btu hr 75 599 kcal hr EXHAUST CONNECTION DIAMETER 12 30 48 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION 3 4 M N P T VOLTAG...

Page 10: ...er Corp 113386 28 ADG 120DR Specifications ________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notic...

Page 11: ...N or in Canada the installation must conform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 L P Gas or LATEST EDITION for General Installation and Gas Plumbing T...

Page 12: ...re the exhaust transition piece to the dryer NOTE It is recommended that this joint be taped as well as all other duct joints to prevent moisture and lint from escaping into the building Dryer Enclosu...

Page 13: ...the area must be increased by approximately thirty three percent Make up air openings should not be located in an area directly near where exhaust vents exit the building It is not necessary to have...

Page 14: ...RTANT Exhaust back pressure measured by a manometer at the dryer exhaust duct area must be no less than 0 and must not exceed 0 3 in WC 0 75 mb 75 Pa NOTE When the exhaust ductwork passes through a wa...

Page 15: ...l ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts the duct to be added should overlap the duct to which it...

Page 16: ...T Exhaust back pressure measured by a manometer at each dryer exhaust duct area must be no less than 0 and must not exceed 0 3 in WC 0 75 mb 75 Pa For extended ductwork runs the cross section area of...

Page 17: ...me without notice or obligation Electrical Service Specifications 3 Wire is available 12 8 14 3 Wire is available 12 8 14 Electric Reversing ELECTRICAL SERVICE SPECIFICATIONS PER DRYER IMPORTANT NOTES...

Page 18: ...ty and any other relevant statutory regulations It is important that gas pressure regulators meet applicable pressure requirements and that gas meters be rated for the total amount of all the applianc...

Page 19: ...dryer must be connected to the type of heat gas indicated on the dryer data label If this information does not agree with the type of gas available do not operate the dryer Contact the reseller who so...

Page 20: ...P T 1 B S P T for CE and AGA dryers inlet pipe connection extending out the back area of the burner box The minimum pipe size connection supply line to the dryer is 1 1 4 diameter For ease of servicin...

Page 21: ...ns made by a qualified professional to ensure that the installation is adequate and conforms to local and state regulations or codes IMPORTANT Failure to comply with the requirements stipulated in thi...

Page 22: ...damage to the steam coil due to the overhung weight of the steam solenoid valve The supply and return line should be insulated This will save energy and provide safety for the operator and maintenanc...

Page 23: ...ections will void warranty If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold freezing temperatures provisions must be made to protect these water...

Page 24: ...a coupling must be used to provide the minimum 1 2 supply feed line If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold freezing temperatures prov...

Page 25: ...________________________ _________________________________________________________________________________________________________________________________ _____________________________________________...

Page 26: ...kPa L P Gas 10 5 in WC 26 1 mb 2 61 kPa IMPORTANT There is no regulator provided in an L P dryer The water column pressure must be regulated at the source L P tank or an external regulator must be ad...

Page 27: ...Once the Cool Down Cycle begins at the end of the heat cycle the L E D display will read COOL DOWN TEMP ___ ___ MINUTES REMAINING At the end of the heat cycle the dryer will shut off the heat and con...

Page 28: ...y is handled in an expeditious manner Parts Replacement parts should be purchased from the reseller from whom the equipment was purchased If the reseller cannot be contacted or is unknown contact the...

Page 29: ...espondence pertaining to the returned part s must be included inside the package with the failed merchandise Each part must be tagged with the following information Model number and serial number of t...

Page 30: ...e damper to bind or stick A back draft damper that is sticking partially closed can result in slow drying and shutdown of the heat circuit safety switches or thermostats If the hi limit trips due to a...

Page 31: ...icator dots in the microprocessor controller computer L E D display are on Refer to the illustration below Procedure for Functional Check of Replacement Components ________ Phase 7 Microprocessor Cont...

Page 32: ...l the drum temperature has dropped below 100 F 38 C The clear stop button on the Phase 7 keypad must be pressed to clear the error condition The open burner hi limit must be reset manually prior to th...

Page 33: ...IL SWITCH CLOSED FAULT Sail switch is closed should be open at the start of a cycle O O O SAIL SWITCH OPEN FAULT Sail switch remained open after the cycle started Should have closed BURNER HIGH LIMIT...

Page 34: ...ADC Part No 113386 28 02 05 15...

Reviews: