Electrical Connections

NOTE: 

A wiring diagram is included with each dryer and is

affixed to the rear upper right guard/panel of the dryer.

Grounding

A ground (earth) connection must be provided and installed
in accordance with state and local codes.  In the absence of
these codes, grounding must conform to applicable
requirements of the National Electrical Code ANSI/NFPA NO.
70-LATEST EDITION, or in Canada, the installation must
conform to applicable Canada Standards: Canadian Electrical
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
The ground connection may be to a proven earth ground at
the location service panel.

NOTE:

 A grounding connection (terminal lug) is provided in

the dryer’s electrical service/relay box at the rear.

For added personal safety, when possible, it is suggested
that a separate ground wire (sized per local codes) be
connected from the ground connection of the dryer to a
grounded cold water pipe.  Do not ground to a gas or hot
water pipe.  The grounded cold water pipe must have metal
to metal connections all the way to electrical ground.  If there
are any nonmetallic interruptions, such as a meter, pump,
plastic, rubber, or other insulating connectors, they must be
jumped out with no. 4 copper wire and securely clamped to
bare metal at both ends.

IMPORTANT: 

For personal safety and proper operation, the

dryer must be grounded.  For proper operation of the
microprocessor controller (computer), an earth (zero) ground
is required.

NOTE: 

Grounding via metallic electrical conduit (pipe) is not

recommended.

Gas Information ______________________

It is your responsibility to have all plumbing connections made
by a qualified professional to ensure that the gas plumbing
installation is adequate and conforms to local and state
regulations or codes.  In the absence of such codes, all
plumbing connections, materials, and workmanship must
conform to the applicable requirements of the National Fuel
Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the
Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural
Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST
EDITION.
In Australia, the fuel gas code is AS/NZS5601, local authority,
gas, electricity, and any other relevant statutory regulations.
It is important that gas pressure regulators meet applicable
pressure requirements, and that gas meters be rated for the
total amount of all the appliance Btu being supplied.

IMPORTANT:

 Failure to comply with these codes or

ordinances, and/or the requirements stipulated in this manual,
can result in personal injury and improper operation of the
dryer.

The dryer and its individual shutoff valves must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 psig (3.5 kPa).  The dryer must be isolated from the gas
supply piping system by closing its individual manual shutoff
valve during any pressure test of the gas supply system at
test pressures equal to or less than 1/2 psig (3.5 kPa).

IMPORTANT:

 Failure to isolate or disconnect the dryer from

supply as noted can cause irreparable damage to the gas
valve voiding the warranty.

Fire or explosion could result.

!

 WARNING

The only electrical input
connections to the dryer
are the 3-phase (3ø) power
leads (L1, L2, and L3),
GROUND, and in the case
of 4-wire service, the
neutral.  Providing local
codes permit, power
connections to the dryer
can be made by the use of
a flexible UL listed cord/
pigtail (wire size must
conform to rating of the
dryer), or the dryer can be
hard wired directly to the service breaker.  In all cases, a
strain relief must be used where the wire(s) enters the dryer
electrical service (relay) box.

Gas Model and Steam Model Dryers

These electrical connections are made at the terminal block
located in the electric service/relay box at the rear, upper left
hand corner of the dryer.  To gain access into this service
box, the service cover (upper back guard) must be removed.

Electric Model Dryers

For electric model dryers made to operate at 208 VAC or
230/240 VAC, the electrical input connection is made into
the terminal block located at the upper rear of the dryer (refer
to the illustration below).  For electric model dryers made to
operate at 380 VAC, 416 VAC, 440 VAC, or 480 VAC, the
electrical input connection is made to the oven relay located
at the upper rear of the dryer (refer to the illustration below).
Input connection wiring must be sized properly to handle the
dryer’s current draw.  This information is printed on the dryer’s
data label.

NOTE: 

A circuit servicing each dryer must be provided.

Summary of Contents for AD-120ES

Page 1: ...ez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Ne pas entre...

Page 2: ...___________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or...

Page 3: ...brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING Children should not be allowed to play on or near the dryer s Children should be supervised if near...

Page 4: ...perate dryer according to this manual and operator s manuals included with dryer may result in conditions which can cause serious injury death and or property damage Safety Precautions _______________...

Page 5: ...anufacturer s Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed from the...

Page 6: ...1 791 cfm 50 71 cmm EXHAUST CONNECTION DIAMETER 14 35 56 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A OVEN SIZE kW Btu hr kcal hr 72 245 700 61 900 75 6 258 000 65 000 VOLTAGE AVAILABLE...

Page 7: ...dclaundry com 7 AD 120ES Specifications __________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice...

Page 8: ...nufacturer reserves the right to make changes in specifications at any time without notice or obligation AD 120ES Specifications __________________________________________________________ WITH OPTIONA...

Page 9: ...OW 1 750 cfm 49 55 cmm HEAT INPUT 300 000 Btu hr 75 599 kcal hr EXHAUST CONNECTION DIAMETER 12 30 48 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION 3 4 M N P T VOLTAG...

Page 10: ...er Corp 113386 28 ADG 120DR Specifications ________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notic...

Page 11: ...N or in Canada the installation must conform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 L P Gas or LATEST EDITION for General Installation and Gas Plumbing T...

Page 12: ...re the exhaust transition piece to the dryer NOTE It is recommended that this joint be taped as well as all other duct joints to prevent moisture and lint from escaping into the building Dryer Enclosu...

Page 13: ...the area must be increased by approximately thirty three percent Make up air openings should not be located in an area directly near where exhaust vents exit the building It is not necessary to have...

Page 14: ...RTANT Exhaust back pressure measured by a manometer at the dryer exhaust duct area must be no less than 0 and must not exceed 0 3 in WC 0 75 mb 75 Pa NOTE When the exhaust ductwork passes through a wa...

Page 15: ...l ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts the duct to be added should overlap the duct to which it...

Page 16: ...T Exhaust back pressure measured by a manometer at each dryer exhaust duct area must be no less than 0 and must not exceed 0 3 in WC 0 75 mb 75 Pa For extended ductwork runs the cross section area of...

Page 17: ...me without notice or obligation Electrical Service Specifications 3 Wire is available 12 8 14 3 Wire is available 12 8 14 Electric Reversing ELECTRICAL SERVICE SPECIFICATIONS PER DRYER IMPORTANT NOTES...

Page 18: ...ty and any other relevant statutory regulations It is important that gas pressure regulators meet applicable pressure requirements and that gas meters be rated for the total amount of all the applianc...

Page 19: ...dryer must be connected to the type of heat gas indicated on the dryer data label If this information does not agree with the type of gas available do not operate the dryer Contact the reseller who so...

Page 20: ...P T 1 B S P T for CE and AGA dryers inlet pipe connection extending out the back area of the burner box The minimum pipe size connection supply line to the dryer is 1 1 4 diameter For ease of servicin...

Page 21: ...ns made by a qualified professional to ensure that the installation is adequate and conforms to local and state regulations or codes IMPORTANT Failure to comply with the requirements stipulated in thi...

Page 22: ...damage to the steam coil due to the overhung weight of the steam solenoid valve The supply and return line should be insulated This will save energy and provide safety for the operator and maintenanc...

Page 23: ...ections will void warranty If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold freezing temperatures provisions must be made to protect these water...

Page 24: ...a coupling must be used to provide the minimum 1 2 supply feed line If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold freezing temperatures prov...

Page 25: ...________________________ _________________________________________________________________________________________________________________________________ _____________________________________________...

Page 26: ...kPa L P Gas 10 5 in WC 26 1 mb 2 61 kPa IMPORTANT There is no regulator provided in an L P dryer The water column pressure must be regulated at the source L P tank or an external regulator must be ad...

Page 27: ...Once the Cool Down Cycle begins at the end of the heat cycle the L E D display will read COOL DOWN TEMP ___ ___ MINUTES REMAINING At the end of the heat cycle the dryer will shut off the heat and con...

Page 28: ...y is handled in an expeditious manner Parts Replacement parts should be purchased from the reseller from whom the equipment was purchased If the reseller cannot be contacted or is unknown contact the...

Page 29: ...espondence pertaining to the returned part s must be included inside the package with the failed merchandise Each part must be tagged with the following information Model number and serial number of t...

Page 30: ...e damper to bind or stick A back draft damper that is sticking partially closed can result in slow drying and shutdown of the heat circuit safety switches or thermostats If the hi limit trips due to a...

Page 31: ...icator dots in the microprocessor controller computer L E D display are on Refer to the illustration below Procedure for Functional Check of Replacement Components ________ Phase 7 Microprocessor Cont...

Page 32: ...l the drum temperature has dropped below 100 F 38 C The clear stop button on the Phase 7 keypad must be pressed to clear the error condition The open burner hi limit must be reset manually prior to th...

Page 33: ...IL SWITCH CLOSED FAULT Sail switch is closed should be open at the start of a cycle O O O SAIL SWITCH OPEN FAULT Sail switch remained open after the cycle started Should have closed BURNER HIGH LIMIT...

Page 34: ...ADC Part No 113386 28 02 05 15...

Reviews: