Preparation for Operation ____________
The following items should be checked before attempting to
operate the dryer:
Read all “CAUTION,” “WARNING,” and “DIRECTION” labels
attached to the dryer.
Check incoming supply voltage to be sure that it is the same
as indicated on the dryer data label. In case of 208 VAC or
230/240 VAC, the supply voltage must match the electric
service exactly.
Electrical power must be provided to the dryer at all
times. If the main electrical power supply to the dryer
is disconnected, the fire suppression system is
inoperative!!
!
WARNING
NOTES __________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________
ELECTRICAL SHOCK HAZARD
Electrical shock hazard can result in serious injury.
If the water dispensing system is activated do not
attempt to operate the dryer.
If the water dispensing system is activated have the
dryer inspected by a qualified agency before operating
the dryer.
!
WARNING
GAS MODELS – check to ensure that the dryer is connected
to the type of heat/gas indicated on the dryer data label.
GAS MODELS – the sail switch damper assembly was
installed and adjusted at the factory prior to shipping.
However, each sail switch adjustment must be checked to
ensure that this important safety control is functioning.
GAS MODELS – be sure that all gas shutoff valves are in the
open position.
Be sure all back panels (guards) and electric box covers have
been replaced.
Check all service doors to ensure that they are closed and
secured in place.
Be sure lint drawer is securely in place.
NOTE:
Lint drawer must be all the way in place to activate
safety switch otherwise the dryer will not start.
Rotate the tumbler by hand to be sure it moves freely.
Check bolts, nuts, screws, terminals, and fittings for security.
STEAM MODELS – check to ensure air supply (80 psi [5.51
bar, 551 kPa]) is on all dryers equipped with standard
pneumatic steam damper system.
STEAM MODELS – check to ensure all steam shutoff valves
are open.
STEAM MODELS with Standard Pneumatic Damper – check
steam damper operation.
STEAM MODELS with Optional Steam Solenoid Valve –
Check steam solenoid valve connections.
Check tumbler bearing setscrews to ensure they are all tight.