Summary of Contents for L-810 SBOL

Page 1: ...L 810 SBOL Steady Burning Obstruction Light Single and Dual User Manual 96A0006 Rev N 2018 11 01 ...

Page 2: ......

Page 3: ...d are guaranteed to be merchantable and fit for the ordinary purposes for which such products are made ADB SAFEGATE L858 Airfield Guidance Signs are warranted against mechanical and physical defects in design or manufacture for a period of 2 years from date of installation per FAA AC 150 5345 44 applicable edition Note See your sales order contract for a complete warranty description All Products ...

Page 4: ...cement parts or accessories Failing to make sure that auxiliary equipment complies with approval agency requirements local codes and all applicable safety standards if not in contradiction with the general rules Using materials or auxiliary equipment that are inappropriate or incompatible with your ADB SAFEGATE equipment Allowing unskilled personnel to perform any task on or with the equipment ADB...

Page 5: ...ation 13 5 2 1 Placement 13 5 2 2 Single L 810 6 6A or 120 Vac Wiring Procedure 14 5 3 Dual L 810 6 6 A Wiring Procedure Without Lamp Out Relay 14 5 4 Dual L 810 120 Vac Wiring Procedure Without Lamp Out Relay 15 5 5 Dual L 810 120 Vac Wiring Procedure With Lamp Out Relay 15 6 0 Maintenance 17 7 0 Parts 19 7 1 Spare Components 19 7 2 L 810 Obstruction Light Parts List 20 7 2 1 Single L 810 Obstruc...

Page 6: ...L 810 SBOL Steady Burning Obstruction Light Single and Dual TABLE OF CONTENTS vi Copyright ADB Safegate All Rights Reserved ...

Page 7: ...o observe this warning may result in personal injury death or equipment damage ARC Flash may cause blindness severe burns or death WARNING Wear personal protective equipment Failure to observe may result in serious injury WARNING Do not touch Failure to observe this warning may result in personal injury death or equipment damage CAUTION Failure to observe a caution may result in equipment damage Q...

Page 8: ...ed by applicable safety regulations If safety devices must be removed for installation install them immediately after the work is completed and check them for proper functioning prior to returning power to the circuit Failure to follow this instruction can result in serious injury or equipment damage Additional Reference Materials Important Information IEC International Standards and Conformity As...

Page 9: ...ons can result in death or equipment damage 1 1 5 Material Handling Precautions ESD CAUTION Electrostatic Sensitive Devices This equipment may contain electrostatic devices Protect from electrostatic discharge Electronic modules and components should be touched only when this is unavoidable e g soldering replacement Before touching any component of the cabinet you shall bring your body to the same...

Page 10: ...L 810 SBOL Steady Burning Obstruction Light Single and Dual Safety 4 Copyright ADB Safegate All Rights Reserved ...

Page 11: ... necessary to Install Carry Out Maintenance Carry Out Troubleshooting on the SBOL 2 1 1 How to work with the manual 1 Familiarize yourself with the structure and content 2 Carry out the actions completely and in the given sequence 96A0006 Rev N 2018 11 01 5 Copyright ADB Safegate All Rights Reserved ...

Page 12: ...L 810 SBOL Steady Burning Obstruction Light Single and Dual L 810 SBOL 6 Copyright ADB Safegate All Rights Reserved ...

Page 13: ...an activate an alarm user supplied in case of lamp failure Mounting Hub Three optional mounting ports are available for the dual L 810 with the lamp out relay option standard bottom port 1 inch 11 5 TPI NPT side port 1 inch 11 5 TPI NPT side port 0 75 inch 14 TPI NPT Units without lamp out relay option standard bottom port 1 inch 11 5 TPI NPT Optional Lamps 45 W 6 6 A 69 W 120 VAC Lamp Life 120 VA...

Page 14: ...he backup lamp 2 At the same time 120 VAC power is also switched to the alarm terminal which can be used to activate a user supplied alarm Packaging Single Actual fixture 5 63 dia 8 09 H in 14 30 dia 20 55 H cm In cardboard box 6 H 6 W 8 5 D in 15 24 H 15 24 W 21 59 D cm Net weight 4 lb 1 81 kg Dual L 810 SBOL Steady Burning Obstruction Light Single and Dual Introduction 8 Copyright ADB Safegate A...

Page 15: ... NPT Bottom Port Standard 2 1 inch 11 5 TPI NPT Side Port Special Order 3 0 75 inch 14 TPI NPT Side Port Special Order Notes ETL Certified 44C100 X X 44C1532 X X 1 X 3 2 Options This subsection describes optional parts for the L 810 obstruction light 3 2 1 Lamp Out Relay An optional lamp out relay is available for the dual 120 Vac L 810 fixtures only The lamp out relay switches the 120 Vac power t...

Page 16: ... used for dual L 810 with relay Not applicable As required Alarm if used for dual L 810 with relay Not applicable 1 Isolation transformer for series circuit powered units Refer to Table 4 1 1 Table 3 Wiring Size 120 V Obstruction Light AWG Single L 810 without relay 14 Dual L 810 without relay 14 Single with relay 16 600 V minimum Dual L 810 with relay 16 600 V minimum Table 4 Isolation Transforme...

Page 17: ...al L 810 fixture energizes a relay and the normally operating lamp 1 If lamp 1 fails the relay is de energized causing the 120 VAC to be switched to the backup lamp 2 At the same time 120 VAC power is also switched to the alarm terminal which can be used to activate a user supplied alarm 96A0006 Rev N 2018 11 01 11 Copyright ADB Safegate All Rights Reserved ...

Page 18: ...L 810 SBOL Steady Burning Obstruction Light Single and Dual Specifications 12 Copyright ADB Safegate All Rights Reserved ...

Page 19: ...amage to the carton that might lead to detection of equipment damage If you note any damage to any equipment file a claim with the carrier immediately The carrier may need to inspect the equipment 5 2 Installation This subsection provides installation instructions for L 810 obstruction light fixtures 5 2 1 Placement The placement and number of L 810 light fixtures required to adequately mark an ob...

Page 20: ...t Lamp Out Relay Note This procedure is for dual L 810 6 6A light fixtures not using lamp out relays To connect the dual L 810 wiring without lamp out relay perform the following procedure 1 Disassemble the dual L 810 light assembly by removing lens clamps lenses lid and lamp sockets 2 See Figure 1 Connect the ends of one 14 AWG customer supplied wire 3 between terminals B and C 3 Feed two custome...

Page 21: ...and lenses 5 Install the L 810 light fixture into the lighting system CAUTION Take up the wire slack as needed Do not put tension on the wires 5 5 Dual L 810 120 Vac Wiring Procedure With Lamp Out Relay Note This procedure is for dual L 810 120 Vac light fixtures with lamp out relays Refer to Lamp Out Relay in the Description section To connect the dual L 810 120 Vac wiring with lamp out relay per...

Page 22: ...p the wire slack as needed Do not put tension on the wires Figure 2 Dual with Relay L 810 Wiring L 810 SBOL Steady Burning Obstruction Light Single and Dual Installation 16 Copyright ADB Safegate All Rights Reserved ...

Page 23: ...13 for lamp replacement Note During lamp replacement clean lens and receptacle and check all wiring for defects Annually When obstruction lights are mounted on disconnect hangers check lowering devices Clean and lubricate all lowering devices such as wire guides pulleys all fittings supports and cables Clean the contact surfaces of the electrical disconnect Table 6 Lamp Replacement Schedule If you...

Page 24: ...L 810 SBOL Steady Burning Obstruction Light Single and Dual Maintenance 18 Copyright ADB Safegate All Rights Reserved ...

Page 25: ...rts correctly 7 1 Spare Components Description Part No Gasket 63B0015 1 Lamp 45 W 6 6 A 48A0007 Lamp 69 W 120 VAC 48A0009 Lamp 116 W 120 VAC 48A0010 Lamp out relay 53A0232 Lens clamp clamp lever 61A0130 Lens collar 2 required per lens 62B0457S Lens red 63A0149 Socket 45 W 6 6 A 49A0002 Socket 69 W 116 W 120 130 VAC 49A0014 96A0006 Rev N 2018 11 01 19 Copyright ADB Safegate All Rights Reserved ...

Page 26: ... ITEM NO PART NUMBER PART NAME DESCRIPTION UNITS QTY A1 Spare Components L810 SINGLE HEAD ASSY EA 1 L1 Spare Components LAMP EA 1 H1 61A0239 1 16 SST CABLE FT 0 75 M1 62B0457 COLLAR CASTING L810 EA 2 H2 63A0149 LENS RED L861 EA 1 M2 63B0015 1 GASKET EA 1 H3 64A0191 12 8 32 X 3 4 PAN HD PHIL EA 2 H4 66A0026 15 8 SPLIT LOCKWASHER EA 1 H5 70A0056 TERM RING 16 12AWG 8 NOINSUL EA 2 L 810 SBOL Steady Bu...

Page 27: ...MP LEVER EA 4 H3 61A0239 1 16 SST CABLE FT 1 5 M1 62B0457 COLLAR CASTING L810 EA 4 M2 62C0467 BASE L810 DUAL EA 1 M3 62C0468 LID L810 DUAL EA 1 H4 63A0149 LENS RED L861 EA 2 H5 63B0015 1 GASKET EA 2 H6 64A0191 12 8 32 X 3 4 PAN HD PHIL EA 4 H7 64A0191 20 8 32 X 1 1 4 PAN HD PHIL EA 4 H8 64A0198 6 6 32 X 3 8 PAN HD PHIL EA 8 H9 66A0026 11 6 SPLIT LOCKWASHER EA 8 H10 66A0026 15 8 SPLIT LOCKWASHER EA...

Page 28: ...BL1 42A0252 LABEL L810 EA 1 L1 Spare Components LAMP EA 2 H1 49A0014 LAMP SOCKET 660W 250V ROUND EA 2 K1 53A0232 RELAY EA 1 H2 61A0130 CLAMP LEVER EA 4 H3 61A0239 1 16 SST CABLE FT 1 5 M1 62B0457 COLLAR CASTING L810 EA 4 M2 62C0468 LID L810 DUAL EA 1 M3 SEE CHART L810D BASE BOTTOM HUB EA 1 L 810 SBOL Steady Burning Obstruction Light Single and Dual Parts 22 Copyright ADB Safegate All Rights Reserv...

Page 29: ...0 H10 64A0274 12 4 X 3 4 TEK II PH PH HD SD ST EA 2 H11 66A0026 11 6 SPLIT LOCKWASHER EA 10 H12 66A0026 15 8 SPLIT LOCKWASHER EA 8 H13 70A0056 TERM RING 16 12AWG 8 NOINSUL EA 4 H17 64A0026 10 6 32 x 5 8 FLATHEAD PHILLIPS SCREW EA 1 TB KI T 94A0457 TERM BLK WIRE KIT EA 1 7 2 4 Dual with Relay L 810 Wiring Schematic Figure 6 shows the wiring schematic for the dual with relay L 810 Figure 6 Dual with...

Page 30: ...L 810 SBOL Steady Burning Obstruction Light Single and Dual Parts 24 Copyright ADB Safegate All Rights Reserved ...

Page 31: ...ll When you have an airfield lighting or system control system problem it is our goal to support airfield maintenance staff as quickly as possible To support this effort we ask that you have the following information ready before calling The airport code If not with an airport then company name prefer customer id number Contact phone number and email address Product with part number preferable or ...

Page 32: ...omponents and sub contractor operations ADB Safegate offers a recycling program for our products to all customers worldwide whether or not the products were sold within the EU ADB Safegate products and or specific electrical and electronic component parts which are fully removed separated from any customer equipment and returned will be accepted for our recycling program All items returned must be...

Page 33: ...adbsafegate com ADB SAFEGATE Malmo ADB Safegate Sweden Address Djurhagegatan 19 SE 213 76 Malmö Sweden Phone Fax Contact Tel 46 0 40 699 17 00 Fax 46 0 40 699 17 30 Email marketing adbsafegate com Internet www adbsafegate com ADB Safegate Airfield Technologies Ltd China ADB Safegate China Address Unit 603 D Block CAMIC International Convention Center No 3 Hua Jia Di East road ChaoYang district Bei...

Page 34: ......

Reviews: