CAUTION
Take up the wire slack as needed. Do not put tension on the wires.
5.4 Dual L-810 (120 Vac) Wiring Procedure (Without Lamp-Out Relay)
To connect the dual L-810 120 Vac wiring without lamp-out relay, perform the following procedure:
1. Disassemble the dual L-810 light assembly by removing lens clamps, lenses, lid, and lamp sockets.
2. See
Figure 1
. Feed four 14 AWG customer-supplied wires (3) through the light base and connect the wires to the lamp
socket terminals A, B, C, and D. Add customer-supplied wire grommets (2) to wires for strain relief before feeding through
the lamp base.
3. Connect one power lead (5) to the ends of the two wires from terminals B and D and connect the other power lead wire to
wires from terminals A and C with customer-supplied wire nuts (4).
4. Reassemble the L-810 light fixture with two 69-watt lamps and lenses.
5. Install the L-810 light fixture into the lighting system.
CAUTION
Take up the wire slack as needed. Do not put tension on the wires.
5.5 Dual L-810 (120 Vac) Wiring Procedure (With Lamp-Out Relay)
Note
This procedure is for dual L-810 (120 Vac) light fixtures with lamp-out relays. Refer to Lamp-Out Relay in the
Description section.
To connect the dual L-810 120 Vac wiring with lamp-out relay, perform the following procedure:
1. Disassemble the dual L-810 light assembly by removing lens clamps, lenses, and lid.
2. See
Figure 2
. Feed 120 Vac power supply lines (14 AWG, 300 V) through the port (either bottom or side).
Note
You must special order the optional side port.
3. See
Figure 6
. Connect the terminal block TB1 terminals TB1-1 (neutral) and TB1-2 (120 Vac).
Note
Before connecting wires to the terminal block, add wire grommets for strain relief.
4. Connect alarm leads to TB1 pin 5 and pin 1.
5. Reassemble the L-810 light fixture and install two 69-watt lamps.
96A0006, Rev. N, 2018/11/01
15
Copyright
©
ADB Safegate, All Rights Reserved