Description
Remote
Master
Dimensions (W x H x D) / Weight
208 x 78 x 142 / 2.2 kg (single Remote) / 2.3
kg (dual)
435.8 x 177.5 x 421.5mm / 22.3 kg
Lamp failure reaction
Short is placed across isolation transformer
as soon as lamp flament failure detected
-
Power Storage after Power-Off
Remote does not reset and remains in
operation, if circuit power loss < 1.5 sec.
Remote start up time is less than 1 sec.
-
Circuit Specifications
Cable type L-824 is recommended, for example FLYCY or equivalent. The following parameters (
∗
) represent the specific
characteristic needed in an equivalent L-824 cable. Reuse of existing installations and layout with maximum cable length or
number of lights to be verified.
Cable type (specification)
L-824
Capacity of the cable
<165 nF/km
1
Inductance of the cable
<0.20 mH/km
1
typical impedance (125 kHz)
35 Ohm
Attenuation of the signal at 125 kHz
<5.8 dB/km
1
Length of serial circuit
20 km roundtrip (12.4 miles)
maximum
Insulation resistance of the series circuit against the L-824 shield or ground
50 Megaohms minimum
2
Secondary transformer attenuation
≤ 23 dB at 100 kHz
1
Notes
1
Contact ADB SAFEGATE for support
2
Technical requirement, not excluding ICAO /FAA compliance